background image

14

  

  

Installation

Informer-IP Wall Mount Series B (Model I-IPW)

Figure 5 Internal Wiring for the Informer-IP Wall Mount

1461179 (JP7)

KEYPAD

SPEAKER

TR

ANSFORMER

RED

BLK

BRN

BLU

BLK

WHT
GRN

TB1

TB2

TB3

GND1

GND3

GND2

GRN

FIELD

WIRING

H
N
G

L
N
G

1751557 (JP8)

C1

R14

D1

R11

R20

R22

R5

C31

C32

C3

C9

R1

C37

R25

C63

R37

C93

Q4

R40

R156

C75

R45

Q2

R28

U8

C52

C59

TP4

D16

C2

C20

R10

R19

R21

C5

R13

R8

R6

R3

R39

D39

R150

C92

C40

Q1

F2

D42

C72

U5

R44

R75

R81

C46

C44

D41

R43

R78

TP3

R153

C128

R76
R79

R90

R89

C79

R49

R91

C16

Y3

C49

U7

R38

R31

R33

C78

R35

R36

TP1

R63

C61

C62

C34

D15

JP3

D40

C47

C100

C64

R42

C70

R46

R60

R59

C85

C86

C55

C88

D11

C57

C90

C29

C22

C26

R9

C28

C36

C25

R24

C8

C4

L1

J1

TP7

C96

U22

R83

TP8

C66

C98

TP6

C69

C95

R86

D8

D7

R27

C41

D4

R15

C12

R16

C15

C87

C48

R32

R66

R73

R64

R53

R67

R54

C81

R56

R57

R72

R70

JP2

R82

U4

U3

C21

C23

C33

R23

C35

C6

C68

C73

C67

R41

C99

R80

C129

R149

J3

C83

JP5

TP2

C27

C7

C38

R2

R26

C43

R85

C24

R7

R4

D3

D18

C82

C76

D14

JP7

C74

R47

U19

C94

R77

JP9

R84

D6

C42

C45

C13

C11

C14

R18

R17

U18

C80

R50

R51

R68

C71

FL1

U10

C54

C50

L3

D9

Q3

U9

C53

R30

R34

R29

C51

C91

C18

C19

L2

D5

R58 R69

R71

R65

TP5

C60

U15

R55

U1

R12

R74

U23

U20

R52

-

+

X1

JP8

U13

C65

C77

D10

C10

C84

R62

R61

R48

+

C89

+

-

AC

AC

D12

C56

M1

C97

R88

C17

C39

JP4

D13

JP10

R87

T1

F

JP1

U2

J2

D2

F1

Y1

U17

JP6

L4

U21

U6

C30

A1

M2

- +

K1

L5

U16

C58

-  +

1.6A

+12V

15

16

2

1

18

63

64

+5V

34
33

48
47

POWER

17

LINE OUT

+9V

MIC A

UD

1.6A

SPEAKER

I2C POR

T

GND

2005579

32

49

50

+3.3V

MIC

31

SPKR LEVEL

SPKR A

UDIO

 TO (J2)

CO
M

T1

2005062__

K1

K2

JP2

R4

D1

Q2

-

+

Q1

R3

D2

-

+

NC

NO
CO
M

NC

Q3

C1

C4

C3

U1

R1

JP1

R8

R7

C6

R5

C2

JP3

R2

600 OHM

NO

C5

LE

VE

L

STROBE

+

RED (COM2)

RED (N.O.2)

BLK

BLK

RED

RED

-

BLK

STROBE OPTION

2005579

2005062

ALL WIRING PROVIDED STANDARD

T300218-05-076

T300218-05-075

17500289

17500288

17500260

17500291

17500292

17500290

TB2

TB3

GND2

TB1

GND1

GND3

The Informer-IP Wall Mount is internally wired.

Summary of Contents for Informer-IP Wall Mount B Series

Page 1: ...right 2019 Federal Signal Corporation Informer IP Wall Mount Model I IPW Series B Two Way IP enabled Intercom and Alarm Initiation Point Strobe is optional Version 3 2 0 1 and later Description Specif...

Page 2: ...nty is in lieu of all other warranties express or implied contractual or statutory including but not limited to the warranty of merchantability warranty of fitness for a particular purpose and any war...

Page 3: ...Installation 10 Determine a Suitable Location 10 Wall Mounting 11 Recessed Mounting 12 Wiring the Device 13 Memory Card Removal and Installation 15 Testing and Training 15 Operations 15 Controls 16 V...

Page 4: ...Table 9 RS232 Connector Pin out 18 Table 10 J2 Input Power from transformer 19 Table 11 JP3 on the main PCB Microphone Enable Jumper 19 Table 12 Replacement Part Numbers 19 Figures Figure 1 Informer I...

Page 5: ...y to confirm that it will be operational in an emergency Safety Messages to Installers People s lives depend on your safe installation of our products It is important to follow all instructions shippe...

Page 6: ...ctions to refer to the system may not provide the intended audible warning and service personnel may be exposed to death permanent hearing loss or other bodily injury File these instructions in a safe...

Page 7: ...trobe Using existing network infrastructure significantly lowers installation costs and simplifies wide scale deployments The Informer IP provides an unmatched value for two way indoor alert and notif...

Page 8: ...B Informer IP requires Federal Signal Commander application software There is a programming fee associated with Informer IPs programmed at the factory Contact your local representative for a quotatio...

Page 9: ...2014 mode B units shipped after February 2014 mode A Standby 60 mA With siren or message audio 110 mA Audio Data Playback Storage 17 hours and 4 000 messages with 2 G microSD card Audio Frequency res...

Page 10: ...r that it is connected to Agency Compliance Complies with UL 60065 and C22 2 No 60065 Installation Read and adhere to all safety warnings in this manual before installing the Informer IP To prevent in...

Page 11: ...as eight holes two sets of four located on the back of the unit that accepts 8 screws Mounting location determines which set of four holes are used Exterior wiring can enter the Informer IP through an...

Page 12: ...re placed into material that can adequately support the weight of the Informer IP Figure 4 Side View Hole Measurements To recess mount do the following 1 Cut a hole that is 8 25 x 7 25 x 3 inches H x...

Page 13: ...and components 5 Connect the wires to the terminal block by inserting the stripped ends of the wires into the connectors as far as they can travel Connect the earth ground to the terminal block posit...

Page 14: ...3 C33 R23 C35 C6 C68 C73 C67 R41 C99 R80 C129 R149 J3 C83 JP5 TP2 C27 C7 C38 R2 R26 C43 R85 C24 R7 R4 D3 D18 C82 C76 D14 JP7 C74 R47 U19 C94 R77 JP9 R84 D6 C42 C45 C13 C11 C14 R18 R17 U18 C80 R50 R51...

Page 15: ...the following Test the Informer IP and all accessories from the control point s to ensure it is operating properly Ensure all users are properly trained to use the system before putting the Informer...

Page 16: ...t and Talk LEDs Scrolling Message Display Relay Outputs REPLAY The REPLAY button replays last voice message received if the red alert light is blinking If the Alert light is not blinking the event has...

Page 17: ...Intercom chat session ends when the control point Ends the Call or Resets the device The following indicators are for troubleshooting purposes only These indicators are not visible when the unit is c...

Page 18: ...lly closed relay 1 5 Common relay 1 6 Normally open relay 1 7 600 ohms audio output 8 600 ohms audio output Alert Rear Input Located on the inside of the Informer IP Wall Mount housing is a two positi...

Page 19: ...on the PCB is JP3 which normally has a shorting plug to enable the built in microphone functionality Model I IPW Series B of the Informer series uses the speaker as the microphone Table 11 JP3 on the...

Page 20: ...34 3400 extension 7511 or Technical Support at 800 524 3021 or 708 534 3400 extension 7329 or through e mail at techsupport fedsig com For instruction manuals and information on related products visit...

Reviews: