15
Installation
Description, Specifications, and Installation Manual
Figure 4 Rack Mount Dimensions
14.18
6.05
1.70
18.98
1.25
18.28
.41
Connect each I-IPSIU to the LAN using CAT5 cable. If the Wired Ethernet has PoE, no
other power connection is required.
If PoE is not available, run the supplied 9 Vdc power supply against the wall and plugged
into a 120 Vac, 60 Hz outlet. Plug the low voltage end of the cord into the power jack
located at the rear of the I-IPSIU. Route the cord to ensure it is protected against walking
on, tripping over or pinching the cord.
Wall Mounting
The I-IPSIU can also be wall mounted by moving the mounting brackets. Before
mounting the unit, determine a suitable location considering the criteria listed. Ensure
the screws are placed into material that can adequately support the weight of the I-IPSIU.
The maximum bolt diameter that fits the bracket slot when mounting to drywall is #12.
Ensure that the screws are tightened sufficiently to securely fasten the I-IPSIU against the
wall.
Figure 5 Attach Bracket