Installation
Informer Sensor/Radio Interface Unit (Model I-IPSIU)
Electrical Code Compliance
Complies with UL 60065 and CAN/CSA Std. C22.2 No. 60065
Installation
Read and adhere to all safety warnings in this manual before installing the
I-IPSIU.
To prevent injury, this apparatus must be securely attached to the wall in
accordance with the installation instructions.
Electrocution or severe personal injury can occur when making electrical
connections, drilling holes, or lifting equipment. Therefore, experienced
electricians in accordance with national and local electrical codes, acting
under the direction of the installation crew safety foreman, should perform
installation.
Determine a Suitable Location
When choosing a location for the I-IPSIU, consider the following criteria:
1. Place as far as possible from electrically noisy electronic devices to avoid
interference. Examples of noisy devices may include the following: microwave
ovens, motor driven devices, light ballasts, and electrical switching devices.
2. Requires a connection to a wired or wireless Ethernet network depending on the
model purchased. Ethernet wire runs must be less than 328 feet from the nearest
network switch.
3. Rack or wall mounting is recommended after you have found a suitable location.
4. Place within six feet of an AC power receptacle to eliminate the need for an
extension cord unless a Power over Ethernet (PoE) connection is available.
Rack Mounting
The I-IPSIU is designed for 19-inch rack mount. Attach the bracket to the I-IPSIU with
supplied screws.
Figure 3 Attach Bracket