Installing the FireRay
DAMAGE TO LIGHT: When installing the light on a vehicle,
you MUST use the manufacturer’s supplied mounting gasket,
screws, and screw grommets. Do not use an impact drill or an
electric screw gun when installing the light. Torque the mounting
screws to the manufacturer’s recommended specification of
7.8-11.3 in-lb. Failure to observe these precautions damages the
light and void any warranty claims for the light.
DRILLING PRECAUTIONS: When drilling holes, check the area
you are drilling into to ensure that you do not damage vehicle
components while drilling. All drilled holes should be de-burred,
and all sharp edges should be smoothed. All wire routings going
through drilled holes should be protected by a grommet or
convolute/split loom tubing.
3.
Drill two 1/4-inch mounting holes and a 1-inch wire routing
hole at the previously scribed locations.
4.
Install the two supplied plastic screw grommets into the two
1/4-inch mounting holes.
NOTE:
When removing the light, inspect the mounting
grommets for wear and replace them as needed.
5.
Complete the electrical connections as described in the
Making Electrical Connections section. The FireRay warning
light assembly has two, three or four 7.8-inch long lead
wires that exit the back of the unit for making electrical
connections.
6.
Align the utility light heads warning light assembly with the
previously inserted plastic screw grommets and secure with
the provided #8 x 1 inch stainless steel screws.
Figure 2 Exploded view - no bezel