Refrigerated Self-Serve Merchandiser (High Profile)
Page 14
Alternate Electronic Temperature Control
Power on/off: Press and hold to turn system on or off.
Set: Press and hold to enter the set point adjustment menu.
Defrost: Press and hold to initiate a manual defrost.
Up: Change set points when in set point adjustment menu.
When not in set point menu, shows maximum temperature of
air discharge probe.
Down: Change set points when in set point adjustment menu.
When not in set point menu, shows minimum temperature of
air discharge probe.
Display indication symbols
On
Compressor on
Flashing Minimum compressor off time in progress
On
Unit in defrost mode
Flashing Defrost delay
On
Condenser fan running
Flashing Minimum condenser fan off time in progress
On
Alarm occurring. See error code section below.
On
Indicates temperature unit of measure.
Powering on control
To turn refrigeration control power on
, press and hold
“ ” for approx. three seconds. The display
will read the probe temperature when on. When the control powers on, the display will read the
current probe temperature. The compressor and condenser fan run indicators ( & ) will illuminate
on the display, meaning that the compressor and condenser fan are running. (Note: the control may
already be in the on mode when shipped from factory).
To turn refrigeration control power to off
, press and hold
“ ” for approx. three seconds. When the
control powers off the display will read
“OFF”. When refrigeration control is in the off-mode cabinet
lights and evaporator fans will still operate, but the compressor will not turn on causing the case to
gradually reach room temperature.