Installation and Operation Instructions

Vertical Freezers & Refrigerators

Low Temperature Glass door Merchandisers

ULG30BS

ULG50BC

ULG80BC

T30LGP

T50LGP

T80LGP

Medium Temperature Glass door Merchandisers

T30MGP

T50MGP

T80MGP

Low Temperature Storage Cabinets

T30LSP

T50LSP

T80LSP

Ice Cream Hardening Cabinets

T30HSP

T50HSQL

T50HSQHP

T50HSP

IMPORTANT

THE REFERENCE INFORMATION FOR THE TABLE

BELOW SHOULD BE FILLED IN AT THE TIME OF

INITIAL START-UP

MODEL NO

.

SERIAL NO.

INSTALLATION DATE

INVOICE DATE

START-UP DATE

SERVICING CO.

SERVICE CO PHONE

part number: 51-5862-00

Summary of Contents for T30HSP

Page 1: ...ss door Merchandisers T30MGP T50MGP T80MGP Low Temperature Storage Cabinets T30LSP T50LSP T80LSP Ice Cream Hardening Cabinets T30HSP T50HSQL T50HSQHP T50HSP IMPORTANT THE REFERENCE INFORMATION FOR THE...

Page 2: ...STANCE For Customer Service or Technical Assistance please call our manufacturing facility toll free number 1 888 650 9799 or 1 864 260 6600 Our Customer Service Representative and Engineers are willi...

Page 3: ...nches between the back of the cabinet and wall for proper air circulation through the condensing unit Installing the Cabinet Models with Top Mounted Compressors Whenever possible leave the crate skid...

Page 4: ...e removable without the use of a tool At the time of initial installation all shelf bracket screws should be loosened with a tool and re tightened hand tight Floor sealing of cabinets without legs or...

Page 5: ...be removed as follows 1 Open the door 180 and support the outer edge Remove the screws in the upper hinge at the cabinet leaving the hinge attached to the door Lift and remove from lower hinge pin CAU...

Page 6: ...The heating element used to vaporize the water in the pan can get quite hot After unplugging the unit allow 10 minutes for it to cool prior to removing the pan The pan is located on the bottom of the...

Page 7: ...r a failure to close the door fully To initiate a defrost manually press and hold the lower button for 4 seconds Note For all units with top mounted compressors the thermostat is located directly on t...

Page 8: ...tactor and the compressor will run As the temperature falls to the set point the control will de energize the compressor relay After 8 hours of operation or other interval specified in param d03 the u...

Page 9: ...efrigeration system capacity low due to Professional service required provide service defective component or refrigerant charge agent with unit s model serial no at time of service request Compressor...

Page 10: ...n irregular surface Level or support unit silicon seal base to floor Unit Noisy Service level problems Refrigerant flood Request professional service back fan blade contact incidental component contac...