INSTRUCTIONS FOR THE DANFOSS DIGITAL THERMOSTAT / CONTROL

Changing the Set Point

Manual Defrost

Occasionally, the user may need to over-ride the automatic defrost system. This can occur if the evaporator

becomes abnormally frost bound due to excessive humidity or a failure to close the door fully.

To initiate a defrost manually press and hold the lower button for 4 seconds

Note: For all units with top mounted compressors, the thermostat is located directly on the top front panel, for bottom

mount units, the visible control unit is a temperature/status display only. On these units the lower panel must be removed

to access the thermostat. Be careful when removing the panel not to impart too much force on the display cable

Summary of Contents for T30HSP

Page 1: ...ss door Merchandisers T30MGP T50MGP T80MGP Low Temperature Storage Cabinets T30LSP T50LSP T80LSP Ice Cream Hardening Cabinets T30HSP T50HSQL T50HSQHP T50HSP IMPORTANT THE REFERENCE INFORMATION FOR THE...

Page 2: ...STANCE For Customer Service or Technical Assistance please call our manufacturing facility toll free number 1 888 650 9799 or 1 864 260 6600 Our Customer Service Representative and Engineers are willi...

Page 3: ...nches between the back of the cabinet and wall for proper air circulation through the condensing unit Installing the Cabinet Models with Top Mounted Compressors Whenever possible leave the crate skid...

Page 4: ...e removable without the use of a tool At the time of initial installation all shelf bracket screws should be loosened with a tool and re tightened hand tight Floor sealing of cabinets without legs or...

Page 5: ...be removed as follows 1 Open the door 180 and support the outer edge Remove the screws in the upper hinge at the cabinet leaving the hinge attached to the door Lift and remove from lower hinge pin CAU...

Page 6: ...The heating element used to vaporize the water in the pan can get quite hot After unplugging the unit allow 10 minutes for it to cool prior to removing the pan The pan is located on the bottom of the...

Page 7: ...r a failure to close the door fully To initiate a defrost manually press and hold the lower button for 4 seconds Note For all units with top mounted compressors the thermostat is located directly on t...

Page 8: ...tactor and the compressor will run As the temperature falls to the set point the control will de energize the compressor relay After 8 hours of operation or other interval specified in param d03 the u...

Page 9: ...efrigeration system capacity low due to Professional service required provide service defective component or refrigerant charge agent with unit s model serial no at time of service request Compressor...

Page 10: ...n irregular surface Level or support unit silicon seal base to floor Unit Noisy Service level problems Refrigerant flood Request professional service back fan blade contact incidental component contac...

Reviews: