background image

LT4935 (1:01/08) 

16 

260mmCRS.

30mm

460mm

FIX 4 OFF EYE

IN POSITIONS

SHOWN

 

TENSIONING NUT

CLAMP SCREW

 

Flip the slide control lever round so 
that the rubber-capped end is 
protruding out to the right as shown 
in the left-hand picture. Check that it 
slides freely up and down in the 
nylon slide guides. Remove the 
nylock nut with a 7mm A/F spanner 
as shown 

ENIGMA II SLIMLINE SLIDE 

Installation Instructions

 

 

SECTION NINE  

To Install the Appliance Continued 

 

OPTIONAL CABLE FIXING SYSTEM

  

It is recommended that the appliance be secured to 
the  fireplace  fascia  with  screws  and  wall  plugs 
supplied. The cable fixing should only be used when 
fixing to 18" openings or when it is desirable not  to 
drill  the  fireplace  fascia.  It  may  not  be  possible  to 
use  the  cable  fixing  system  with  some  pre-cast 
flues. 

• 

Drill 4 holes in the rear of the fireplace opening in the 
position  shown  and  fix  securely  the  4  eye  bolt  with 
screws and wall plugs provided. 

• 

Fix  the  fire  casing  back  into  the  opening  using  the 
cable  fixing  system  as  shown  do  not  cut  off  loose  ends  of  cable  after  fixing,  coil  and  tuck 
carefully into space to the sides of the burner unit.  

Note

: When using the cable fixing kit with the spacer, 

fix  and  seal  the  spacer  to  the  rear  of  the  appliance 
flange with the screws and foam seal provided. 
 

Gas Soundness Test 

Turn on  the  gas  supply  to  the  appliance ensuring 
that the restrictor elbow is fully open and check for 
soundness  in  accordance  with  current  codes  of 
practice. 

 

 
 
 

CONNECTING CONTROL LEVER 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for ENIGMA II SLIMLINE SLIDE

Page 1: ...LIMLINE SLIDE OWNER S MANUAL Please read these instructions carefully before you start using the appliance Keep this booklet handy for future reference This appliance is for use in GREAT BRITAIN or IR...

Page 2: ...ass Two Fabricated Metal 14 Clearance to Shelf or Surround 14 Clearances at Side of Fire 14 SECTION NINE To Install the Appliance 15 Checking the Flue and Fire Opening 15 Connecting the Gas Supply 15...

Page 3: ...Use disposable gloves facemasks and eye protection After handling wash hands and other exposed parts If a vacuum is used for cleaning the coals or cleaning after servicing installation it is recommend...

Page 4: ...low the lever to spring up the pilot light should remain alight and the main burner should light on its low setting c Should the pilot fail to light pull the lever fully up to turn off the appliance w...

Page 5: ...BED Some soot deposits will form on the coals this is perfectly normal and adds to the realism of the appliance USE ONLY THE COALS PROVIDED AND NO ADDITIONAL COALS MUST ADDED The Loose coal set consis...

Page 6: ...ge to coals to have rough sides forward and make sure that they are stable in their positions Place five coals between the first row of coals and the rear matrix as shown Arrange them to look as rando...

Page 7: ...louration of the firebox sides is also perfectly normal and does not detract from the operation of the fire USE ONLY THE PEBBLES PROVIDED NO ADDITIONAL PEBBLES MUST ADDED The Loose pebble set consists...

Page 8: ...beige colours to give a pleasing layout Place the second row of five large pebbles as shown Again mix the colours Place the top row of four pebbles on top of the rear matrix as shown Place the three...

Page 9: ...taken to avoid contact with the refractory lining this is a delicate surface and should not be wiped or rubbed A vacuum cleaner may only be used after all the loose coals have been removed SECTION FI...

Page 10: ...dard Assessment Procedure SAP for energy rating of dwellings PACK CONTENTS Refractory Fuel Bed Components Appliance Rear Matrix Owners Instruction Front Matrix Wire Fixing Kit Loose Coals Foam Seal Tr...

Page 11: ...ABLE ITEM AND MUST BE EXCHANGED AS A COMPLETE ASSEMBLY USING ONLY THE ORIGINAL MANUFACTURER S PART A non combustible hearth must be provided to comply with the building regulations or a suitable propr...

Page 12: ...debris collection Any permanent flue restriction or variable dampers shall be removed or locked fully open The chimney should be swept prior to installation if not new or previously used with a gas ap...

Page 13: ...a good seal is formed between the rear and base of the appliance and the chimney to avoid any reduction of natural draught A non combustible hearth must be provided beneath the appliance within the fi...

Page 14: ...e the gas supply is to be connected to the appliance This may be done from the front of the unit from either the left or right side or a concealed fitting from the rear Check that the restrictor elbow...

Page 15: ...eing used fix the spacer box to the fireplace first with wood screws and wall plugs then screw firebox to spacer box using screws provided Cut a cross slit in the rubber grommet and feed the appliance...

Page 16: ...openings or when it is desirable not to drill the fireplace fascia It may not be possible to use the cable fixing system with some pre cast flues Drill 4 holes in the rear of the fireplace opening in...

Page 17: ...osition and allow the appliance to run for approximately 5 minutes Check the inlet pressure is 20 1 mbar Fuel Bed Layout IMPORTANT REFER TO THE HEALTH SAFETY NOTICE LOCATED ON PAGE 3 OF THIS BOOKLET B...

Page 18: ...room opened and the extractor fan running at maximum setting Should spillage occur seek expert advice Fit the fire front and trim Fit the trim front with the 4 magnetic strips placed on the vertical...

Page 19: ...t to damage the pilot head Replacement of Gas Control 1 Turn off the gas supply by the isolating cock 2 Remove fire fret 3 Remove all Loose coals or Pebbles 4 Remove moulded refractory parts 5 Remove...

Page 20: ...ning or replacement 4 Re assembly is the reverse of removal Replacement of Oxy Pilot Assembly NOTE If the pilot assembly is replaced it must be replaced by an identical unit from the same manufacturer...

Page 21: ...LT4935 1 01 08 21...

Page 22: ...e found on the label attached to the packaging and on the data badge which is located on the appliance flange top right behind trim Retailer Name ___________________________________________ Address __...

Page 23: ...__________ Address ________________________________ Post Code TELEPHONE No PRODUCT DETAILS Model Enigma II Slimline Slide Serial No Date of Purchase This information can be found on the label attached...

Page 24: ...y Warning Label Fire Guard Warning Label Fire Guard Bag Loose Coals 4795 Loose Pebble Set 4792 Rear Matrix Coal 4794 Rear Matrix Pebble 4791 Front Matrix Coal 4793 Front Matrix Pebble 4790 Magnet Segm...

Reviews: