LT4935 (1:01/08)
18
MOVE IT LEFT AND RIGHT ALL SMOKE MUST BE DRAWN INTO THE FLUE
POSITION HEAD OF SMOKE MATCH UNDER FIRE OPENING AS SHOWN
CLOSE ALL DOORS AND WINDOWS, LEAVE FIRE BURNING FOR TEN MINUTES
ENIGMA II SLIMLINE SLIDE
Installation Instructions
SECTION TEN
Checking Operation of Fire
Checking Product Clearance
•
Check for satisfactory clearance of combustion products, close all doors and windows and
leave fire burning for five minutes.
•
Insert lighted smokes match 10mm into
the fire immediately under the canopy,
move match horizontally along from
one side to the other all the smoke
should be drawn into the flue.
•
If spillage occurs, allow a further 5
minutes. Should spillage still occur,
turn off the fire, remove the restrictor
plate (if fitted) and repeat clearance
otherwise seek expert advice.
•
If an extractor fan is situated in the room this test should be repeated with the fan running. If
there is a connected room with an extractor fan, the test should be repeated with all the
doors to that room opened and the extractor fan running at maximum setting. Should
spillage occur seek expert advice.
Fit the fire front and trim
•
Fit the trim front with the 4 magnetic strips placed on the vertical side flanges of the firebox -
one on the top and one at the bottom of each side, and fit the fire front.
•
Offer the decorative trim up squarely and centrally and push into position.
ADVISE CUSTOMER THAT:
The curing effect of heating the fuel bed and other ceramic components will cause an initial
odour. This is due to the starch used in the manufacturing process and is non-toxic. Any
debris should be cleaned from the appliance. A vacuum cleaner can be used but only after
all the loose coals or pebbles have been removed. The appliance should be serviced
annually by a competent person in accordance with these instructions and the appliance
checked for spillage in accordance with the method detailed in these instructions.
Demonstrate the lighting and extinguishing procedures to the user and the removal and
refitting of the decorative trim for cleaning.
If ventilation is fitted for any reason it must be checked regularly to ensure freedom from
obstructions.
Hand these instructions over to the user.
Summary of Contents for ENIGMA II SLIMLINE SLIDE
Page 21: ...LT4935 1 01 08 21...