![Fbt VAIE 2000 Manual Download Page 90](http://html.mh-extra.com/html/fbt/vaie-2000/vaie-2000_manual_547128090.webp)
VAIE 2000 | Voice Alarm Integrated Systems
System Manual | 2013
UK
0
VAC 2006 • VAR 2006
8.2 <MuSIC> MEnu
Setting the audio parameters of the BGM sources
Music source control panel, shown by the
VAC 2006
in normal “quiescent Condition”.
•
Indications on the display
A) General output volume of the BGM Source
B) Status labels of each of the 6 zones:
oFF
Music disabled
ndB
Music enabled with the associated output volume
CALL
Call in progress from a “voice” source (PA Source).
nA
Line not active.
C) BGM Source selected for the “music” channel.
D) PA Source active on the “voice” channel for service announcements.
note:
The VAC 2006 system enables service announcements to be made from a PA Source to the required zones while continuing to broadcast
music to all the other zones not affected by the call. When an announcement is being made, the display will show the source that is being used
on the voice channel (
d
), and the status label of each zone selected (
B
) will indicate the word CALL.
Service announcements will be broadcast at the volume set for the input of the PA Source (see AUDIO SETTINGS menu) and if appropriate will
also be sent to the zones for which music is de-activated (OFF).
•
navigation keys
MENU: For accessing the MAIN page
Ok: For selecting a source of BGM
kEYS 1 to 6: For selecting music zones
RESET: Not operational
ALERT: Not operational
EVAC: Not operational
8.2.1 Selection of a BGM Source for the “music” channel
Press
oK
to select the required source of music from among the following:
• AUX
Microphone source connected to the LINE AUX IN input
(R7)
.
• REMOTE Source selected by the secondary VAC 2006 via the
VAC 2006 LINk socket (R3).
• INPUT 1
Microphone source connected to the IN 1 input
(R6).
• INPUT 2
Microphone source connected to the IN 2 input
(LINE or MIC sockets) (R5).
• NO INPUT No input selected.
8.2.2 overall volume control of the “music” channel BGM Source
• Use the
+/-
knob to adjust the volume.
The attenuation setting is visible directly on the display (
A
), with variations of 1 dB.
The volume that is set is stored for each BGM Source selected.
8.2.3 Adjustment of the music volume for each output zone
• Hold the numerical key of the required zone (from 1 to 6) down and turn the
+/-
knob.
The output volume is adjustable to any of 5 levels of attenuation in respect of the master volume (
A
); the attenuation steps are as follows:
-15dB
(maximum attenuation),
-9dB
,
-6dB
,
-3dB
,
0dB
(no attenuation).
The volume that is set refers only to the “Music” channel.
N.B.: Adjustment is not possible on those lines to which an VAR 2006 router is connected.
8.2.4 Activation and de-activation of music for each output zone
• Press and then release the numerical key of the required zone
(from 1 to 6).
The status label (B) will switch between
oFF
(music disabled) and ndB (music
on
and associated output volume).