8–1
S E C T I O N 8
Installer Modes
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Entering Installer Modes
There are 4 installer modes in the panel.
TO ENTER INSTALLER MODES: [CODE][*][INSTALLER][X]
Where:
[CODE]
Press the CODE button
[*]
Press the asterisk (*) button
[INSTALLER] Enter the 4-digit installer code (default = 2468)
[X]
Press the single digit indicating the Installer mode, as follows:
1 Installer Keypad Programming
Press [1] & [3] (at the same time
SYSTEM DEFAULT
Press [7] & [9] (at the same time) USER CODE DEFAULT
Press [*] [#] [X] [X]
RF PROGRAMMING
2 (Not Used)
3 Unattended Download
4 On-line Download
5 Walk Test (Reduced Gain) Mode
Installer Mode 1 (Installer Keypad Programming)
Installer Mode 1 enters the installer into the Keypad Programming mode. Refer to Section
11: Data Entry Via LED Based Keypads.
The EZ-Mate Downloader Software contains an option to inhibit keypad programming. If you
select it, you will hear a negative acknowledgment (4 short beeps) after you attempt to enter
this mode. The software has another option (Default Lockout) to inhibit a different installer
from defaulting the panel and entering keypad programming. This prevents hostile account
takeovers.
Installer Mode 1 (System Default)
You can initiate a system default through the keypad by pressing the “1” and “3” keys at
the same time, while in the Programming mode. The system will then default (revert to
factory-programmed values) and go through the reset sequence. You can also initiate a
system default by removing power (AC and DC), shorting JP1 and JP2, reapplying power
(with JP1 and JP2 still intact) waiting 8 seconds, and then removing the short with power
still applied. NOTE: You can select a programming option can be selected through the
EZ-Mate Downloader Software called Default Lockout. If you select it, a system default
reset will change all of the programmable options with the exception of the CSID (a code
used by the software to identify the panel during remote connections) and the Installer code.
This prevents hostile account takeovers.
Installer Mode 1 (User Code Default)
The User codes can be reset to factory default values (User Code 1 = 1234) by pressing the
“7” and “9” keys at the same time, while in the Programming mode. The user codes will
default and the system will go through the reset sequence.
Summary of Contents for XL-20
Page 9: ...XL 20 Hookup and Installation Instructions 1 2...
Page 19: ...XL 20 Hookup and Installation Instructions 4 2...
Page 23: ...XL 20 Hookup and Installation Instructions 5 4...
Page 33: ...XL 20 Hookup and Installation Instructions 8 4...
Page 63: ...XL 20 Hookup and Installation Instructions 11 4...
Page 65: ...XL 20 Hookup and Installation Instructions 12 2...
Page 71: ...XL 20 Hookup and Installation Instructions A 6...
Page 75: ...XL 20 Hookup and Installation Instructions B 4...
Page 77: ...XL 20 Hookup and Installation Instructions C 2...
Page 79: ...XL 20 Hookup and Installation Instructions D 2...
Page 81: ...XL 20 Hookup and Installation Instructions E 2...
Page 82: ...Notes...
Page 83: ...1 9 Gl N9825V1 04 98 Copyright 1998 PITTWAY CORPORATION...