A1. SAFETY
A1.2 Nitrogen (N2)
In addition to making sure to follow proper safety protocols for CO2 as stated in Section 1.2, strict attention must also be
observed in the prevention of N2 gas leaks in the frozen drink system. If an N2 gas leak is suspected, immediately ventilate
the contaminated area before attending to repair the leak. Inhalation of excessive amounts of N2 can cause dizziness,
nausea, vomiting, loss of consciousness, and death.
To avoid personal injury and/or property damage, always secure N2 cylinders in an upright position with a safety chain. An
N2 cylinder with a damaged or detached valve can cause serious personal injury.
A3. SPECIFICATIONS
A3.1 General Requirements
A5. INSTALLATION
A5.5 Connecting to Water Supply
Connection to a potable water supply should be carried out in the same manner as specified in Section 5.5; however, the
bulkhead fitting diagram used for Nitrofub configurations is shown in Figure A5.1. Please use this diagram as a reference
for water, syrup, CO2 and N2 connections.
Requirement
N2 Supply Pressure
70 - 72 PSIG (483 - 496 kPag)