37X INSTALLATION & OPERATION MANUAL
372/373 MODEL
34
Message
Meaning
Action
OFF
Barrel is turned off.
Select the ON option in the pop-up
menu.
READY
Barrel is ready for serving.
Enjoy a frozen beverage.
REFRIGERATION SENSOR
FAILURE
Low side pressure transducer
reading out of range.
Verify harness is plugged into
transducer. Replace transducer if
necessary.
SLEEPING
Dispenser is in sleep mode.
Wait until the normal wake time or
restart each barrel by turning ON.
SYRUP OUT
The syrup pressure is below the
syrup out threshold.
Check syrup BIB or pump.
Replace BIB, if needed (barrel will
restart automatically).
TEMPERATURE SENSOR
FAILURE
Temperature sensor reading out of
range.
Check sensor and replace if
necessary.
WAITING TO DEFROST
Barrel is waiting to begin the defrost
cycle and must wait until one of
other barrels freezes or completes
a defrost.
No action required.
WAITING TO FREEZE
Barrel is ready to freeze but is
waiting on one of the other barrels
to complete defrost.
Wait until barrel defrosting has
completed the defrost cycle.
WATER OUT
Water supply turned off.
Restore water supply. Dispenser
will automatically restart.