37X INSTALLATION & OPERATION MANUAL
372/373 MODEL
35
11.2 Fault Codes
NF*
The dispenser records all errors, or faults, that occur. A history of these faults can be found in the FAULT CODE HISTORY
menu located in the SERVICE MENU. Each error has a three digit number associated with it. The first two digits are the
error number and the third digit is the barrel number with the error. If the third digit is a 0 (zero) then the error is a common
error to all barrels or it's a dispenser error.
Error #011, 012, 013: Syrup Out
The syrup pressure is less than 45 PSIG (310 kPag).
Error #020: CO2 Out
The CO2 pressure is less than 45 PSIG (310 kPag).
Error #030: Water Out
The water pressure is less than 45 PSIG (310 kPag).
1
Replace the empty BIB.
2
Ensure the CO2 line is connected to the BIB pump.
3
Ensure the BIB pump is operating correctly.
4
Ensure the CO2 tank is not empty.
5
Ensure the syrup shutoff valve at the solution module is turned on.
6
Ensure any syrup shutoff valves at the back of the dispenser are not turned off.
7
Ensure the syrup supply pressure at the dispenser is reading 70 PSIG (483 kPag). Adjust the
regulator if needed.
8
Ensure the syrup pressure transducer is connected and working properly.
1
Replace or refill the CO2 tank.
2
Ensure CO2 shutoff valve at the back of the dispenser is not turned off.
3
Ensure the CO2 pressure transducer is connected and working properly.
4
Ensure the CO2 supply pressure at the dispenser is reading 70 PSIG (483 kPag). Adjust the regulator
if needed.
1
Ensure the water line to the dispenser is on and that the water shutoff at the solution module is
turned on.
2
Ensure the CO2 supply line is connected to the water pump and that the pump is not stalled.
3
Ensure the CO2 supply pressure at the dispenser is reading 70 PSIG (483 kPag). Adjust the regulator
if needed.
4
Ensure the water pressure transducer is connected and working properly.
* Refer to Appendices for additional information on Nitrofub configuration.