5.5 Checking the water level, topping up
NOTICE!
Dirty or contaminated water can block the nozzles!
–
Fill only with clean water.
NOTICE!
Components may get damaged by frost!
–
Drain all water off if there is a risk of frost.
–
The water system can alternatively be filled with an
anti-freeze mixture.
ENVIRONMENT!
Anti-freeze mixture is an environmentally haz-
ardous substance
After the frost period drain off the anti-freeze mixture,
catch it and dispose of environmentally.
1.
Check the water tank filling level, replenish as necessary.
2.
For filling up remove the locking cap and fill in clean water.
The water tank can alternatively also be removed for filling.
1.
Pull the hose (1) off the water tank.
2.
Pull out the spring pin (2).
3.
Pull out the bolt (3) and take off the water tank.
4.
Insert the bolt through the guides on the water tank and
insert the spring pin to lock.
ð
The water tank can now be carried by the bolt.
Fig. 20
Fig. 21