![Fayat Bomag BM 500/15 Original Operating Instructions Download Page 12](http://html1.mh-extra.com/html/fayat/bomag-bm-500-15/bomag-bm-500-15_original-operating-instructions_546874012.webp)
32
6 First steps
6.4 Symbols and displays in the working window
1) Designation of the sensor selected from the sensor selection menu for the
corresponding control loop (also see “6.6 Sensor selection”)
2) The actual values; i.e. the current values measured by the two active sensors
of the left and right control loop are displayed with signs as well as their physical
measuring unit.
3) The target values for the two active sensors of the left and right control loop
with signs.
4) The cross slope arrows only are displayed if the Cross Slope sensor has been
selected as active sensor for one of the two control loops. The cross slope direction
indicated by the arrow is the sign for the value measured by the Cross Slope sensor
(left slope or right slope).
In case a slope sensor is connected but not selected the slope’s actual value and the
symbols for the slope direction appear in an own window.
The resolution and the physical measuring unit of the displayed values are settable in the
configuration menu separately for grade and slope sensors (also see “8.2.2 Changing the
units of measurement”).
5)
At any time, the 4 fields at the bottom of the graphic display show the current function
of the keys situated below the display.
Summary of Contents for Bomag BM 500/15
Page 2: ......