СРС308 Processor Module
The Module Structure and Functioning
C P C 3 0 8 U s e r M a n u a l
© 2 0 1 3 F a s t w e l V e r . 0 0 1 b E
37
Table 3
-
10: The Designation of the Gigabit Ethernet (XP11) Connector Contacts
When making an interface cable for connecting to the XP11 (IDC10) connector, it is recommended
to use the ACS00040-04 additional accessory (see Table 1 3).
3.4.7
SerialATA Interface
There are standard SATA interface connectors (XP7 and XP10) located on the CPC308 module
board. The maximum transmission rate is 300 MB/s.
Fig. 3-16: SATA Connectors (XP7 and XP10)
Table 3
-
11: The Designation of SATA Connectors (XP7 and XP10) Contacts
Contact Number
Function
1
GND
2
TXP
3
TXN
4
GND
5
RXN
6
RXP
7
GND
It recommended to use cables whose length does not exceed 45 cm in order to connect SATA
devices.
Attention!
Connecting and disconnecting standard SATA devices when the module is
switched on may result in the module or power supply breakdown.
It is
permitted to connect and disconnect standard SATA devices only when
the module is switched off!