32
Appendix A
Trouble Shooting
If problems occur, verify the installation of the camera with the instructions in this manual and with other
operating equipment. Isolate the problem to the specific piece of equipment in the system and refer to the
equipment manual for further information.
Problem
Possible Solution
Joystick can’t control system.
1. Check that the dome camera IDs are set
properly (See Figures 1 to 6).
Check the polarity of the data line
Camera number does not match the multiplexer
number.
1. Check the camera ID and insert the BNC
cable into the proper input of the multiplexer.
Forgot password
1.
Consult your supplier, distributor or service
Center
Multiplexer & DVR can’t work with the Joystick
controller.
1.
Check that the data cable for the multiplexer
has the correct Pin configuration (1=1, 2=2,
3=3 .... 8=8).
2.
Check the communication menu of Multiplexer
as per Pages 15 (setting Multiplexer)
Appendix B
SPECIFICATION
Power Consumption
Control Method
Baud Rates
Operating Temperature
Humidity
Storage temperature
Dimension
Weight
Communication
12VDC, 0.5A
RS-485, RS-232C
2400~230K bps
0°C to 50°C(32
o
F to 140
o
F)
0 to 90%RH(non-condensing)
-20°C to 60°C(-40
o
F to 122
o
F)
Professional Joystick : 380x168x96 (HID2404CZx)
Economic Joystick : 380x168x70 (HID2404CLx)
Professional Joystick : 1.2kg
Economic Joystick : 1.1kg
Dome Connection : Max 32
Multiplexer Connection : Max 255
DVR Connection : Max 99
(Design and Product specifications subject to change without notice)
FASTRAX ll KEYBOARD CONTROLLER
50301815A