FAST_EnergyCam_Manual
.docx
| v1.30 | 8. December 2016
page
4
/ 38
The following actions are currently available:
(1 sec) Trigger OCR reading
To trigger an OCR reading outside the default period - the button has to be pressed for 1 second.
(until the “- 1 -“ is visible)
Press Button Release Button
If the device is installed on a meter the display shows:
1) --PIC---
: Trigger OCR reading is started
2) P 15 / P 10 / P 5 / P 2
: the configured reading period (60min, 30min,15 min, 10 min, 5 min, 2 min, 1
min)
2) P ---
: device isn’t installed
3) 1078.4
: the new reading
Button is
pressed
for
Action
Display
after
Button
After that
1 sec
OCR Reading
--Pic---
P 15 / P ---
Device goes into normal
operation
2 sec
Install wM-Bus
--MBus--
e.g. 22048063
(M-Bus ID)
S2 / T2 / Cable
Install wM-Bus and send
default data.
3 sec
Install Device
-INST-BW
-INST-WB
--V2.00--
B (Build#)
If successful – device goes
into normal operation
4 + 1 sec
Reboot
--Reset-
-- EC --
Restart the device / disable
the Data Logger
5 sec
Info
(see below)
(see below)
(see below)
Device goes into normal
operation
5 + 1 sec
Reset
--Reset-
MODBUS
115200
Device is Reset to default
Modbus
6 + 1 sec
Reset
--Reset-
M-BUS
2400
Device is Reset to default M-
Bus