background image

13

Operator manual 

HA180

V. 2.0

3.1.4

Overview of the controls (manual can table version)

A:

Emergency stop switch

B:

Display with indicators and keys

C:

Can table switch

C

B

A

C

Summary of Contents for Harbil HA180

Page 1: ...V 2 0 Fast Fluid Management B V PO Box 220 2170 AE Sassenheim The Netherlands www fast fluid com Operating and Safety manual Harbil HA180...

Page 2: ...f Fast Fluid Management B V to notify any person of such revision or change Details and values given in this manual are average values and have been compiled with care They are not binding however and...

Page 3: ...ack 12 3 1 4 Overview of the controls manual can table version 13 3 1 5 Overview of the controls electrical can table version 14 3 1 6 Overview of the display 15 3 1 7 Type plate serial number 16 3 1...

Page 4: ...ition 28 4 2 1 Move the machine to the final location with a ramp optional 28 4 3 Install the computer 29 4 3 1 Open the side cover 29 4 3 2 Install the computer 29 4 4 Turning on the machine 30 4 5 F...

Page 5: ...other language versions are translations of the original instructions 1 1 How to work with the manual For the safe use of the machine it is important 1 To familiarize yourself with the structure and...

Page 6: ...nsion cords or inadequately rated power cables Make sure that the power cable is freely accessible Do not place objects on top of the machine Keep lids panels and covers closed and in place whenever p...

Page 7: ...the likely Operating Temperature An operational and environmental assessment is required before using flammable colorants in the dispenser taking into account all local circumstances including ventil...

Page 8: ...ting parts hazard Pinch hazard for your hand Read the manual Electrical hazard Pinch hazard for your foot Can table switch up down Return this part to its original position Do not use flammable liquid...

Page 9: ...tally friendly recycling 2 Do not dispose of the machine into domestic waste Dispose of the machine according to local regulations 3 Dispose of the canisters as chemical waste according to the local r...

Page 10: ...erator manual 3 1 Description 3 1 1 Overview of the machine front manual can table version A Top cover B Canister C Pump with nozzle D Front cover E Switch plate F Computer cover G Can table H Wheels...

Page 11: ...A180 V 2 0 3 1 2 Overview of the machine front electrical can table version A Top cover B Canister C Pump with nozzle D Front cover E Switch plate F Computer cover G Can table H Wheels I Brush contain...

Page 12: ...12 Operator manual HA180 V 2 0 3 1 3 Overview of the machine back A Side cover B Power socket C Net entry D Type plate E Knock out plate for ventilation interface B A D E C...

Page 13: ...13 Operator manual HA180 V 2 0 3 1 4 Overview of the controls manual can table version A Emergency stop switch B Display with indicators and keys C Can table switch C B A C...

Page 14: ...14 Operator manual HA180 V 2 0 3 1 5 Overview of the controls electrical can table version A Emergency stop switch B Display with indicators and keys C Can table switch C B A C...

Page 15: ...ense operation See 5 3 for a description of the error codes and the possible causes and solutions Error key When you push the error key the error display shows the program version When you push the er...

Page 16: ...XXX V XX XX Hz XXX W Model XXX XX XXX Brand Xxxxxxxxxxx Serial no XXXXXXXXX XXXXXX Prod week XX XXXX Mass XXXkg Fuse X AT Fast Fluid Management B V IDEX Dispensing P O Box 220 2170 AE Sassenheim The N...

Page 17: ...entation 4 Move the can table down See 3 2 4 5 Remove the can 3 2 2 Place the can 1 Place the can A at the centre of the mark B on the can table 3 2 3 Move up the can table 1 Hold the handle C and pus...

Page 18: ...umentation 1 Place the can See 3 3 2 2 Move the can table up See 3 3 3 3 Choose the recipe and dispense See the software documentation 4 Move the can table down See 3 3 4 5 Remove the can A C A B C WA...

Page 19: ...and stops when the can is in front of the can sensor C 2 After the can table stops release the can table switch 3 3 4 Move down the can table 1 Push and hold the lower part of the can table switch A...

Page 20: ...ly Open the brush drawer 1 Push the front side of the brush drawer until the brush drawer is unlocked 2 Open the brush drawer A Use the handle B Remove the brush container 1 Remove the brush container...

Page 21: ...l of the liquid follow the local regulations Fill the brush container 1 Fill the brush container with the liquid that your paint supplier indicates The level of the liquid must be between the MIN and...

Page 22: ...ntainer A in the brush drawer B Close the brush drawer 1 Push the brush drawer A in the machine until the brush drawer is locked A B Note Make sure that the brush container is correctly put in its pos...

Page 23: ...the switch plate 1 Put back the switch plate A a Slide in the switch plate at the back and lift it upward b Make sure that the hooks B are connected to the machine c Slide in the switch plate forward...

Page 24: ...chine stops immediately 2 Solve the problem as quickly as possible Note The software checks the level of colorant in each canister The software on the machine shows when you need to refill a canister...

Page 25: ...he emergency stop switch The machine restarts automatically CAUTION When the machine is shut down the stirring mechanism which is necessary to keep the colorant in optimal condition is also shut down...

Page 26: ...1 Remove the cardboard A and the plastic from the outside of the machine 4 1 2 Remove the transport bracket of the turntable at the rear 1 Remove the fasteners 2 Remove the transport bracket A 4 1 3 R...

Page 27: ...ction on the canisters 1 Open the top cover See 3 4 4 2 Remove the cardboard sheet A and the protective foam B 3 Close the top cover See 3 4 4 4 1 6 Remove the plastic protection from the switchplate...

Page 28: ...to the ground 3 Move the machine to the final location 4 Connect the power cable to the net entry WARNING Mind the minimum requirement of the load capacity of the floor See 6 2 WARNING Do not use a f...

Page 29: ...e side cover 1 Remove the fasteners A 2 Remove the side cover A 4 3 2 Install the computer 5mm A 2 1 A Note Usually the computer already has the correct software and drivers installed If not see the i...

Page 30: ...machine 1 Connect the power cable to the wall socket 2 Make sure that the emergency stop switch is reset See 3 4 5 3 Set the computer switch to ON On the display push the computer switch key You will...

Page 31: ...Possible solution SOS signal during the stirring The agitation motor is malfunctioning a cable is broken or the power board is malfunctioning Contact service See 5 5 1 long interrupted beep continuous...

Page 32: ...ush the computer switch key to restart the machine See 3 1 6 Display shows E13 A turntable timeout occurred Push the computer switch key to restart the machine See 3 1 6 Display shows E33 A valve time...

Page 33: ...cator is on The canister is empty Refill the canister See 3 4 4 Can indicator blinks and is red The can is missing Place the can See 3 2 2 Can indicator blinks and is green The dispense process is fin...

Page 34: ...L 2 3 and 4 6 Pump capacity mL 40 Maximum can height cm 42 Can table dimensions cm 44 x 31 Parameter Specification Dimensions height x width x depth cm 140 x 81 x 94 Packed dimensions height x width...

Page 35: ...out of operation 10 to 12000 Maximum relative humidity RH without condensation 90 Parameter Specification Maximum noise level dB A 65 Parameter Specification IP Ingress Protection classification 32 EM...

Page 36: ...E BLUE YEL GRN YEL GRN YEL GRN BROWN POWER UNIT SUPPLY 110 230VAC 50 60Hz 10Amax FUSE 2 x 10AT OPERATOR DISPLAY TO PC VALVE ENCODER 26 6 2019 BROWN GREY BLACK 1 2 4 3 WHITE YELLOW BROWN GREEN BLACK YE...