Original notice – User’s manual
35
11. TROUBLESHOOTING
“TB” part
PROBLEM
POSSIBLE CAUSE
SOLUTION
The machine does not
start.
The circuit breaker of the
electrical cabinet is open.
Toggle the 2-position switch
to "on".
Emergency stop button on
the control panel is
activated.
Rotate while lifting to bring it
back to its original position.
The oil pressure gauge of
the mandrel holder is not
between 130 and 180 BAR.
Contact us.
The control panel no
longer allows the machine
to be operated.
Lack of energy source.
Follow the manual pumping
procedure below (see also
sticker affixed to the
machine).
Contact us.
“BOX” part
PROBLEM
POSSIBLE CAUSE
SOLUTION
Le moteur ne
démarre pas.
Emergency stop button switched
on.
Disengage the emergency stop
button.
Starter problem.
Contact us.
Battery problem.
Load or change the battery.
Connections from gasoline tank to
engine.
Contact us.
Gasoline level.
Fill the tank with gasoline.
Starter housing.
Contact us.
Electrical connection of the motor. Contact us.
Gasoline solenoid valve.
Contact us.
Air filter and gasoline engine filter. Clean Change engine air and
gasoline filters.
Spark plugs.
Contact us.
The motor
stops under
load.
Gasoline level.
Fill the tank with gasoline.
Air filter and gasoline engine filter. Clean or change engine air and
gasoline filters.
Motor adjustment.
Contact us.
Motor defective.
Contact us.
Le bloc de
compression
ne fournit pas
d’air.
Compression block drive belts.
Change drive belts.
Block air filter clogged.
Clean or change the filter.
Block-tank flexible.
Contact us.
Block defective.
Contact us.