Technical Data
Installation instructions Sauna control Series FCUxx00 / Version V 2.27
9
2
Technical Data
2.1
General information
General data
Designation
Unit
FCU2x00
FCU3x00
FCU4x00
FCU5x00
FCU6x00
Dimensions basic device
[mm]
(H x W x D) 247 x 285 x 86,5
Dimensions operating
element:
(H x W x D)
FCUxxxx DESIGN
[mm]
198,5 x 124 x 30,5
---
---
FCUxxxx DESIGN-GLAS
[mm]
197,5 x 122,5 x 35
---
---
FCU5xxx DESIGN-TOUCH
[mm]
NA
158x104x38
---
FCU6xxx
[mm]
---
Max. Distance
Basic device to operating
element
FCUxxxx DESIGN, FCUxxxx
DESIGN-GLAS or interior
display
[m]
100
Voltage supply
[V AC /
Hz]
see nameplate
Number of temperature
sensors
1
2 (+IR sensor)
safety OFF
[°C]
Sensor interruption (at ca. >138°C)
sensor short circuit (at ca. < -25°C)
STB interruption (at ca. 140°C
accordingly to DIN EN 60335-2-53 section 19)
Humidity Sensor connectable
No
Yes
Yes
Yes
Yes
Timer
Yes
Yes
Yes
Yes
Yes
Week Timer
No
No
Yes
No
No
Light/ Fan dimming
No
Yes
Yes
Yes
Yes
Terminals for power switch
gear
Yes
Ambient condition
Ambient temperature
[°C]
0 to +40
With protective coating -20 to +40
Rel. humidity
[% r.F.]
max.80 % r. humidity, non-condensing
Storage temperature
[°C]
–10 to +60
Storage rel. humidity,
[% r.F.]
max.80 % r. humidity, non-condensing
Insulation type
[–]
IPx4
Table 1: Technical Data – General