Technical Data
Installation instructions Sauna control Series FCUxx00 / Version V 2.27
11
2.3
Voltage and switching capacity - electrical load
Designation
Type
FCU2x00, FCU3x00, FCU4x00, FCU5x00, FCU6x00
Nominal voltage
400 V 3 N ~ 50Hz
Oven
3x 230 V~ max. 3x 3 kW (AC1) / 3x 0,55kW (AC3) / 3x 0,75kW (AC15)
(Inrush current max. 30A for 5ms)
Evaporator
1)
230 V~ max. 3 kW (Inrush current max. 30A for 5ms)
Infrared
2)
230 V~ max. 3 kW (Inrush current max. 120A for 5ms)
PS1 (FLE-STB)
230 V~ max. 60 W (Inrush current max. 30A for 5ms)
Fan
230 V~ max. 15W…120 W (Inrush current max. 10A for 5ms)
Cabin light
230 V~ max. 15W…120 W (Inrush current max. 10A for 5ms)
Cleaning light
230 V~ max. 120 W (Inrush current max. 10A for 5ms)
Color light
3)
OUT 13 … OUT 16, C5
230 V~ / max. 120 W per relay / total capacity see circuit diagram
(Inrush current max. 150A for 20ms)
OUT 1 … OUT 4
3)
OUT 5 … OUT 12
3)
Potential free, safety extra low voltage max. 50 V / 1 A,
230 V~ / max. 120 W per relay; total capacity see circuit diagram (Inrush
current max. 6A for 5ms)
IN 1 … IN 4, IN 9 … 12
3)
IN 5 … IN 8
3)
safety extra low voltage approx. 15 V, switching current approx. 10 mA ,
230 V~ 50 Hz, all inputs same phase
Table 3: Technical data – voltages and switching capacity consumer
1) Only in controls with the bathing option "Sauna with humidity" (Series FCUx200 and FCUx400)
2) Only in controls with the bathing option "Infrared" (Series FCUx400). For full spectrum radiators (e.g. Vitae radiators)
with high inrush currents max. 1,5 kW
3) Optional
NOTE!
FASEL additionally offers a extension power unit for loads of 9 kW, 18
kW and 24 kW.