PERLA HP - ISSUE 02
39
FAS International S.p.A. - Via Lago di Vico, 60 - 36015 SCHIO (VI) Italy - tel. +39 0445 502011 – fax +39 0445 502010 - e-mail:
Command 90 Select AUDIT protocol:
The control board is fitted with a socket for connecting an interface board for protocol RS232 (kit with
082929B board). This kit includes a RS232 socket used to transit the Audit protocol.
If the command is set at 4, the machine dialogue with the outside world is achieved by means of an 082928
infrared interface, based on the specifications of the EVA-DTS protocol.
If the command is set at 5 the machine dialogues with the external world through an infrared 082925
interface (IRDA interface), according to the specifications of the protocol EVA-DTS vers.5.0.
Then, if the preceding option has been set at 4 or 5, the machine proposes selecting the input / output
direction: towards the infrared interface (082928 or 082925 OPTICAL LINK) or towards RS232 (connector
situated on the card). In the latter case the connector pins used are 2= VMC Tx, 3=VMC Rx, 5= GROUND in
which case the transmission speed is fixed at 9600 baud. To select press any key on the keyboard to scroll
the various direction options and confirm the desired value by pressing “B”
If the initial option is set at 5 the machine requests that the peripheral address be inserted: key in the desired
value and press “B".
If the initial option is set at 5 the machine proposes selecting the transmission speed which must be
consistent with the setting of card no. 082925 (see relevant instructions). The setting range is between 2400
baud and 19200 baud. To select press any key on the keyboard to scroll the various speed options and
confirm the desired value by pressing “B”.
If the command is set at 6 the machine dialogues with the user by means of DEX-UCS protocol.
Command 91 Entering machine identification data:
The first item of information required in numeric format of max 8 digits refers to the serial number; the
second in alpha-numeric format of max 32 characters, refers to the machine location; the third item required
is the machine identification numeric code (asset number) of max 12 characters. For details on how to enter
the description in alpha-numeric format, see the table in command 95.
Command 92 Clear sales data:
The command
is used to clear the machine's sales data (see command 10). A special access code must be
entered for this operation. The procedure is as follows:
•
Programming
mode, ........................................................................... Command 0 appears on the display
•
Type 92 and press ENTER, .................................................................. Code 0000 appears on the display
•
Type 1221 and press ENTER, ...................................................... 'CLEAR DATA?' appears on the display
Press the ENTER key to clear all the sales data whereas press ESC to return to the main menus without
saving the changes.
Command 94 Displays the last 10 power-offs:
This command displays the last 10 periods in which the machine has been put off.
The following values are displayed:
POWER
OFF
DATE
TIME
POWER
ON
DATE
TIME
To pass to another display press pushbutton ENTER.
N.B.:
The clock has to be programmed to obtain reliable values.