KT5500 5-
1
/
2
” T
ong
& CLInCHER® B
aCKup
S
ECTIon
C
onTEnTS
2.8
T
ECHnICaL
M
anuaL
C.
HYDRAULIC SCHEMATIC / COMPONENT IDENTIFICATION
Your tong may be equipped with one or two control valves, as well as safety door switch and hydraulics, depending upon
the specific model. Disregard the control valves indicated on the following schematics that do not apply to your model.
Item
Description
Part Number
1
Inlet Valve DVA35-A880 w/2500 TO 3500 DVG35 HMRV CARTRIDGE
10-9016
2
Relief Valve, DVA35-MRV-1
10-0010R
3
Motor Section, DVA35-MA8, 4WAY SAE PORTS
10-9014
4
Backup Section, DVA35-DA8 4WAY SAE PORTS
10-9019
5
Lift Section, DVA-SA8, 1” ORB PORT
10-9015
6
Outlet Section, DVA35-TR99, SAE PORT
10-0086
7
Flow Control Valve, N800S (not shown)
08-9062
8
Pilot-To-Operate Cartridge Valve, LKHC-XDN
08-1625
9
Safety Door Valve Block
101-0727
10
Safety Door Switch
08-0337
11
Check Valve, SH4600
87-0110
12
Rineer GA15-13 Hydraulic Motor
02-9022
13
Relief Valve, RPGC-KAN
08-1180
14
Relief Valve Block, Sun CAJ
08-1844
15
Check Valve, CKEB-XCN
08-0481
16
Check Valve Block, Sun BCJ
08-1327
17
3000 psi Pressure Gauge
02-0245
18
CLINCHER®
Backup Cylinder
1403-00-00B
S
ETup
& o
pERaTIon
P
T
MOTOR
LIFT
14 13
16 15
17
18
18
1
2
3
4
5
6
12
11
9 8
10
7
OPTIONAL
OPTIONAL
OPTIONAL
Summary of Contents for 80-0420-16