ChickenMaster PRO User Guide
Firmware 01.14B
Revision 1.0 23/05/2022
The
Den
, 100 Fox Drive, Dandenong South. Victoria. 3175.
Phone: 0411 479 411
MAIN SETTINGS MENU
SIX Sub Menu Items are available.
Main Settings Menu
MANUAL CONTROL MENU
Main Settings Menu
Manual Control
EXTERNAL DOORS
Pressing and HOLDING the UP arrow button will OPEN the EXTERNAL DOORS.
Pressing and HOLDING the DOWN arrow button will CLOSE the EXTERNAL DOORS.
MANUAL CONTROL of the External Doors can be used even if the ChickenMaster PRO is in the
AUTO OFF position or if the External Doors AUTOMATIC MODE has been DISABLED in settings.
EXTERNAL DOORS are inhibited from operating in MANUAL Control Mode when the
VOLTAGE LOCKOUT Threshold has been reached.
The default Value for this threshold is 11.0 Volts (User Adjustable) with a 1 volt positive Hysteresis (Fixed)
Attempting manual control of the External Doors during VOLTAGE LOCKOUT will display the following screen.
Press the ESCAPE button to exit this screen.
EXTERNAL DOORS settings
SYSTEM SETTINGS required for your ChickenMaster PRO to function correctly
MANUAL CONTROL allows the user to manually control, EXTERNAL DOORS, NEST BOX GATES, INTERNAL
LIGHTING, COURTESY LIGHTS & TEST ALARM/STROBE
INTERNAL LIGHTING settings
NEST BOXES GATES settings
Logs numerous events for fault finding refer page 38 for a list of the types events logged