34
111628M
Revision date: 09.25.18
Quick Start Guide: Additional Drain Manifold Photos
Photos on this page show the assembled drain manifold as attached to the frame. (Manifold can be assembled on a flat surface and
then attached to the frame to allow easier adjustment of the manifold height on the frame if desired.) Dry fit all manifold components
before you secure the horizontal tubes to the 111696 cross fittings only. Coat the outside of one end of a tube and the inside of
fitting with PVC primer and cement. Slide tube into the 111696 fitting. Gently lift the open end of the tube to create a slight slope
toward the center stack. Allow the cement to set and release the tube. Repeat for all remaining horizontal tubes. Install the slip
caps.
Do not secure the slip caps to the ends of the horizontal tubes.
These must remain free to remove so the horizontal
tubes can be cleaned.