ICF-01-2

Copyright © 1998 ffi Corporation

Models:

CIL18
CIL24
CIL28

C O N T E N T S

Safety Precautions . . . . . . . .2
Warranty  . . . . . . . . . . . . . . .2
Installation  . . . . . . . . . . . . . .3
Dimensions  . . . . . . . . . . . . .4
Operation  . . . . . . . . . . . . . .5
Service  . . . . . . . . . . . . . . . .6
Wiring Diagrams  . . . . . . . . .7
Safety Decals  . . . . . . . . . . .9

Operators Manual

f f i C o r p o r a t i o n   /   F a r m   F a n s

Summary of Contents for FFI CIL18

Page 1: ...2 Copyright 1998 ffi Corporation Models CIL18 CIL24 CIL28 C O N T E N T S Safety Precautions 2 Warranty 2 Installation 3 Dimensions 4 Operation 5 Service 6 Wiring Diagrams 7 Safety Decals 9 Operators Manual f f i C o r p o r a t i o n F a r m F a n s ...

Page 2: ...y start without warning when the system is operating on Automatic control Continued safe dependable operation of equipment relies to a great degree upon the operator For a safe and dependable system follow the recommendations within this manual make it a practice to regularly inspect the operation of the system for any unsafe con ditions or developing problems TAKE SPECIAL NOTE OF THE OPERATING PR...

Page 3: ...ed with a fused disconnect switch Locate this switch near the unit as the power should be shut off before opening the control box cover or per forming any service on the unit NOTE The fused dis connect is provided by the owner and MUST BE COR RECTLY SIZED AND CONNECTED TO ALLOW PROPER MOTOR OPERATION UNITS WITHOUT CONTROLS It is the customer s responsibility to provide a fused disconnect and motor...

Page 4: ...ull Load Overload Heater Full Load Overload Relay Heater Element HP Amps Relay Element Amps Part Number Part Number 1 5 3 0 14 27A 056 1062 1 C16 3 056 1143 9 3 4 5 20 27A 056 1062 1 C22 8 056 1166 0 5 7 35 45A 056 1046 4 C30 3 056 1142 1 7 5 10 42 45A 056 1046 4 C33 0 056 1153 8 10 15 55 90A 056 1083 7 F56 7 056 1203 1 ...

Page 5: ...heck the current draw of the motor The motor amperage should not exceed the maximum full load amps listed within Tables 1 and 2 or motor nameplate FAN SHUT DOWN 1 Press the fan STOP button on units equipped with motor controls 2 Shut off electrical power at main and at disconnect 3 Close the roof openings and cover fan inlet to prevent harmful back draft air currents from passing through the grain...

Page 6: ...this time looking for any cracks thread or bolt damage warpage etc Consult your dealer or the factory for any questions concerning damage INSTALLATION 1 Carefully clean motor shaft key bushing and bore of wheel MAKE SURE MAIN POWER IS LOCKED OUT and that shaft and key are completely free of rust and burrs Do NOT lubricate the bushing or capscrews CHECK AND MAKE SURE ALL MOTOR MOUNT BOLTS ARE PROPE...

Page 7: ... Make certain power is shut off and locked out then remove fan guard inlet cone and wheel as outlined earlier 2 Open motor junction box cover and disconnect the motor lead wires from within the box NOTE Tag or otherwise identify wires for ease of reassembly 3 Remove motor mount bolts If there are any shims between the motor and its base note their locations so they can be properly installed during...

Page 8: ...8 Fig 2 Fan control box wiring diagram 230V 3 phase Fig 3 Fan control box wiring diagram 460V 575V 3 phase ...

Page 9: ...read and understood by all people in the grain handling area If a decal is damaged or missing contact ffi Corporation 5900 Elmwood Ave Indianapolis IN 46203 IMPORTANT THIS UNIT IS WIRED FOR 230 VOLT 1 PHASE POWER SUPPLY Typical for 230V 1 phase models ...

Page 10: ...Copyright 1998 ffi Corporation 5900 Elmwood Ave Indianapolis Indiana 46203 7 29 98 ...