CAUTION:  Do not attempt to pull the flange of the
bushing flush with the wheel hub.  A clearance of from
1/8" to 1/4" must be maintained between bushing
flange and wheel hub surface.  

8. Turn wheel by hand and check it for freedom of rotation

and uniform clearance around inlet cone before rein-
stalling the fan guard.

FAN MOTOR REMOVAL & INSTALLATION

In the event of motor failure, remove the motor, as
described, and take it to the nearest Authorized
Service Station.  AUTHORIZED SERVICE STATIONS
ARE THE ONLY PLACES THAT CAN PROVIDE
MOTOR WARRANTY.  Motor service and repair at
other places will be at owner’s expense.

If service station determines motor failure to be caused
by faulty material or workmanship, repair will be under
warranty when within the warranty period.  Motor fail-
ure because of external causes will result in a charge
to the owner for repair.

1. Make certain power is shut off and locked out, then

remove fan guard, inlet cone, and wheel as outlined
earlier.

2. Open motor junction box cover and disconnect the

motor lead wires from within the box.

NOTE: Tag, or otherwise identify wires for ease of
reassembly.

3. Remove motor mount bolts.  If there are any shims

between the motor and its base, note their locations so
they can be properly installed during reassembly.

4. Disconnect the motor end of the motor conduit, if

required, then carefully pull conduit and wires through
hole in the motor junction box. Remove motor.  If motor
requires service, take it to an Authorized Service
Station.

5. To reinstall motor, slide onto motor mount and replace

shims (if required) between motor and mount.
Reinstall motor mount bolts and washers,  and fully
tighten them at this time.

Reinstall conduit and wires and carefully remake all
electrical wiring connections.

NOTE: Make sure to install and tighten the wheel in
accordance with earlier instructions.

W I R I N G   D I A G R A M S

Fig. 1 - Fan control box wiring diagram, 230V 1 phase

Summary of Contents for FFI CIL18

Page 1: ...2 Copyright 1998 ffi Corporation Models CIL18 CIL24 CIL28 C O N T E N T S Safety Precautions 2 Warranty 2 Installation 3 Dimensions 4 Operation 5 Service 6 Wiring Diagrams 7 Safety Decals 9 Operators Manual f f i C o r p o r a t i o n F a r m F a n s ...

Page 2: ...y start without warning when the system is operating on Automatic control Continued safe dependable operation of equipment relies to a great degree upon the operator For a safe and dependable system follow the recommendations within this manual make it a practice to regularly inspect the operation of the system for any unsafe con ditions or developing problems TAKE SPECIAL NOTE OF THE OPERATING PR...

Page 3: ...ed with a fused disconnect switch Locate this switch near the unit as the power should be shut off before opening the control box cover or per forming any service on the unit NOTE The fused dis connect is provided by the owner and MUST BE COR RECTLY SIZED AND CONNECTED TO ALLOW PROPER MOTOR OPERATION UNITS WITHOUT CONTROLS It is the customer s responsibility to provide a fused disconnect and motor...

Page 4: ...ull Load Overload Heater Full Load Overload Relay Heater Element HP Amps Relay Element Amps Part Number Part Number 1 5 3 0 14 27A 056 1062 1 C16 3 056 1143 9 3 4 5 20 27A 056 1062 1 C22 8 056 1166 0 5 7 35 45A 056 1046 4 C30 3 056 1142 1 7 5 10 42 45A 056 1046 4 C33 0 056 1153 8 10 15 55 90A 056 1083 7 F56 7 056 1203 1 ...

Page 5: ...heck the current draw of the motor The motor amperage should not exceed the maximum full load amps listed within Tables 1 and 2 or motor nameplate FAN SHUT DOWN 1 Press the fan STOP button on units equipped with motor controls 2 Shut off electrical power at main and at disconnect 3 Close the roof openings and cover fan inlet to prevent harmful back draft air currents from passing through the grain...

Page 6: ...this time looking for any cracks thread or bolt damage warpage etc Consult your dealer or the factory for any questions concerning damage INSTALLATION 1 Carefully clean motor shaft key bushing and bore of wheel MAKE SURE MAIN POWER IS LOCKED OUT and that shaft and key are completely free of rust and burrs Do NOT lubricate the bushing or capscrews CHECK AND MAKE SURE ALL MOTOR MOUNT BOLTS ARE PROPE...

Page 7: ... Make certain power is shut off and locked out then remove fan guard inlet cone and wheel as outlined earlier 2 Open motor junction box cover and disconnect the motor lead wires from within the box NOTE Tag or otherwise identify wires for ease of reassembly 3 Remove motor mount bolts If there are any shims between the motor and its base note their locations so they can be properly installed during...

Page 8: ...8 Fig 2 Fan control box wiring diagram 230V 3 phase Fig 3 Fan control box wiring diagram 460V 575V 3 phase ...

Page 9: ...read and understood by all people in the grain handling area If a decal is damaged or missing contact ffi Corporation 5900 Elmwood Ave Indianapolis IN 46203 IMPORTANT THIS UNIT IS WIRED FOR 230 VOLT 1 PHASE POWER SUPPLY Typical for 230V 1 phase models ...

Page 10: ...Copyright 1998 ffi Corporation 5900 Elmwood Ave Indianapolis Indiana 46203 7 29 98 ...

Reviews: