7 / 52
www.fanvil.com
Network/SIP
Registration
Network error: Blink with 1s
Network running: Off
Registration failed: Blink with 3s
Registration succeeded: On
B.Start Using
Before you start to use the equipment, please make the following installation.
1. Confirm the connection
Confirm whether the equipment of the power cord, network cable, electric lock control line
connection and the boot-up is normal. (Check the network state of light)
Power, Electric Lock, Indoor switch port
There are 2 power supply options: 12V/DC or POE (Powered By Ethernet). PIN 1 (+12V)
and PIN 2 (VSS) connected to the power supply. PIN3/4/5 used to connect the electric lock, only
2 of them (NC and COM, or NO and COM) will be connected usually, depending on the type of
electric lock. PIN6/7 used to connect indoor switch which control the open/lock of electric lock.
CN7
1
2
3
4
5
6
7
+12V
VSS
NC
COM
NO
S_IN
S_OUT
12V 1A/DC
Electric-lock switch
Indoor switch
Driving mode of electric-lock(Default in Passive mode)
Driving mode of electric-lock decides whether the electric-lock use an independent power supply.
The independent power supply will be required in passive mode, while electric-lock will be
powered by i31S in active mode.
Ǐ
Note
ǐ
When the device is in active mode, it can drive 12V/650mA switch output maximum, to
which a standard electric-lock or another compatible electrical appliance can be connected.
z
When using the active mode, it is 12V DC in output.
z
When using the passive mode, output is short control (normally open mode or normally close
mode).
Jumper in passive mode
Jumper in active mode