50
Output Settings
Output Response
Enable or disable Output Response
Triggered by DTMF
Ring tone
Select the DTMF trigger ring tone.
Triggered by URI
Ringtone
Select the URI trigger ring tone.
Triggered By SMS
Ringtone
Select the SMS trigger ring tone.
Triggered By Dsskey
Ringtone
Select the Dsskey trigger ring tone.
Standard Status
When choosing the low level trigger (NO: normally open), when meet
the trigger condition, trigger the NO port disconnected.
When choosing the high level trigger (NC: normally close), when meet
the trigger condition, trigger the NC port close.
Output Duration
Set the output change duration time, the default is 5 seconds.
Trigger by DTMF
Enable or disable trigger by DTMF. The device will check the received
DTMF sent by remote device, if it matches the DTMF trigger code, the
device will trigger corresponding output port.
DTMF Trigger Code
Input the DTMF trigger code, default value is 1234.
DTMF Reset Code
Input the DTMF reset code, default value is 4321.
Reset By
Reset the output port mode by duration or state.
By duration: Reset the output port status when output duration occurs.
By state: Reset the output port status
when device’s call state
changes.
Trigger by URI
Enable or disable trigger by URI.
User can send commands from remote device or server to i10 series
device, if the command is correct, then device will trigger
corresponding output port.
Trigger Message
Input trigger message for trigger by URI mode.
Rest Message
Input reset message for trigger by URI mode.
Trigger by SMS
Enable or disable trigger by SMS.
User can send ALERT command to i10 series device, if the command
is correct, then device will trigger corresponding output port.
Trigger SMS
Input trigger message for trigger by SMS mode.
Reset SMS
Input reset message for trigger by SMS mode.
Trigger by Input
Select the input port, when the input port meets the trigger condition,
the output port will be triggered (The Port level time change, By <
Output Duration > control)