With C58RF it is possible to know for how many hours the
heating system worked the day before (closed relay – on) and
from the last intellitherm initialization (last reset or battery
insertion).
the display will show the heating working hours, positioning
the switches as indicated in the picture.
s u m m e R / a i R - C o n d i t i o n i n g m o d e
intellitherm C58RF starts the aiR-Conditioning mode moving the switch to the summeR
position . the ComFoRt/tmaX temperature can be regulated pressing the red keys.
the red sectors on the ring indicate what time the air-conditioning is on; the other colours
indicate when the system is oFF.
intellitherm
e n g l i s h
9
move the switch to the eConomY position to read the
minimum temperature or move to the ComFoRt position
to read the maXimum temperature.
With intellitherm C58RF it is possible to verify the minimum
and maXimum temperatures reached the day before and what
time they were measured
move the switch to PRog
A1 A2
t e C H n i C a l F e a t u R e s
in compliance with the standards en 50371, en 60950-1,
en 3000220-2, en 301489-3.
in compliance with the directive 1999/5/eC.
Class a software.
temperature regulation: ComFoRt from 2° to 62°C; eConomY
from 2° to 62°C.
differential: +/- 0,25°C.
thermal gradient: 4°K/h.
oFF mode with optional antifreeze protection (5°C) by a dip switch.
maximum room temperature: t45.
Power supply without connection to the electrical line with 2 aa
1,5V alkaline batteries (1 year battery life).
Radio frequency value: 868.350 mhz = 15mW.
Radio frequency maximum range: 30 meters indoor
(according to the wall conformation); 70 meters outdoor
automatic control of the battery charge; the display will
indicate if the charge is inadequate.
Battery replacement without data dropout.
switch for the winter or summer operating modes.
Reset key to restore the set program.
dimensions: 130 x 80 x 17 mm.
erP classification: erP Class
IV
; 2% (eu Reg. 811/2013
- 813/2013)