Fantini Cosmi C57RF Manual Download Page 6

4

mountinG tHe tHeRmostat BodY 

on tHe Base

5

inseRtinG and RePlaCinG 

tHe BatteRies
insert  two  long  life  aa  1,5V  alkaline  batteries, 

paying  attention  to  the  indicated  polarity. 

Batteries last approximately 2 years: when they 

begin  to  run  down,  the  battery  symbol  starts 

to flash on the display. if the batteries are not 

replaced within 15 days, intellitherm C57RF will 

switch-off  automatically  and  the  display  will 

indicate oFF.

to  separate  the  base  from 

the frontal body, remove the 

battery  cover  and  unscrew 

the  screws,  rotating  the 

thermostat body downwards.

2

3

oFF mode seleCtion
When in oFF mode, intellitherm may be set 

to keep a fixed temperature of 5°C to protect 

the system from the risk of freezing. 

this  selection  must  be  carried  out  during 

the  installation  and  before  inserting  the 

batteries.

note:  if  this  selection  is  needed  to  be 

changed  after  the  installation,  intellitherm 

has to be reset and reprogrammed.

to set the antiFReeze 5°C protection 

move the dip switch HiGH.

to switch the system completely oFF, 

move the dip switch doWn.

1

Wall mountinG

to  be  installed 

b y   q u a l i f i e d 

personnel only!

install  the  programmable  thermostat  at 

1,5  meters  above  the  floor  level,  far  from 

kitchens,  heat  sources,  windows  and  doors. 

make sure the base is fixed to a level surface, 

without strains. 

for flush-mounting 

boxes (3 modules, 503)

for round 

flush-mounting boxes 

i n s t a l l a t i o n

intellitherm

e n g l i s h

6

!

time and day setting keys

to  insert  batteries  remove  the  cover  pulling  it  frontaly 

6

time settinG 

(see the picture on the right)

B 60 mm

AUTO

‘aa’ 

1.5V

 -

 -

‘aa’ 

1.5V

a 83,5 mm

CH173d selF-leaRninG PRoCeduRe

to let communicate a C57RF and a CH173d correctly, it is necessary to follow a procedure called 

“self-learning”; in this way the actuator will recognize and store the C57RF identity and it will be 

in position to perform all its controls, leaving out the controls of other transmitters that may be 

found in the same area (please note that the C57RF/CH173d system range is approximately 30 

meters in free air).

to  perform  the  self-learning  procedure,  proceed  as  follows:  press  the  CH173d  key  for  about  5 

seconds, until the yellow led starts flashing. then press the C57RF Reset key, using a pointed 

object: a few seconds later, the led on the left side of the CH173d will fast flash yellow and then it 

will return green with fixed light, thus indicating that the self-learning is finished. 

note: it is possible to control two or more CH173d actuators with a single C57RF: of course the 

self-learning  procedure  shall  be  performed  on  all  the  CH173d  actuators  (not  necessary  at  the 

same time).

Summary of Contents for C57RF

Page 1: ...C57RF i t a l i a n o pag 2 e n g l i s h pag 6 e s p a o l pag 10 f r a n a i s d e u t s c h pag 14 pag 18 cronotermostato settimanale radiofrequenza...

Page 2: ...onale qualificato Montare il cronotermostato a 1 5 metri di altezza dal pavimento lontano da cucine fonti di calore finestre e porte Assicurarsi che lo zoccolo sia fissato ben in piano e senza deforma...

Page 3: ...er alcuni secondi si annullano tutte le programmazioni e si ripristina il programma standard tasti di regolazione della temperatura massima TMAX COMFORT da 2 a 62 C AUTO funzionamento con programma au...

Page 4: ...e sul display comparir l ora corrispondente 3 4 Al termine delle modifiche posizionare il deviatore per avviare il riscaldamento o su per il raffrescamento Con Intellitherm C57RF possibile in ogni mom...

Page 5: ...rossi si regola la temperatura di COMFORT TMAX da mantenere nell ambiente I settori rossi della corona del display indicano quindi i periodi di accensione dell impianto di condizionamento quelli di a...

Page 6: ...ens heat sources windows and doors Make sure the base is fixed to a level surface without strains for flush mounting boxes 3 modules 503 for round flush mounting boxes A B INSTALLATION Intellitherm e...

Page 7: ...eep it pressed for a few seconds to reset any customization and restore the pre set standard program Maximum temperature keys TMAX COMFORT from 2 to 62 C AUTO operation with the weekly automatic progr...

Page 8: ...has to be changed flashes and corresponding time appears 3 Once the changes are finished position the switch to start the heating or to start the air conditioning With this function C57RF enables you...

Page 9: ...ove to the COMFORT position to read the MAXIMUM temperature With Intellitherm C57RF it is possible to verify the MINIMUM and MAXIMUM temperatures reached the day before and what time they were measure...

Page 10: ...ndicando que se efectu el autoaprendizaje NOTA Es posible dirigir dos o m s accionadores CH173D con un solo C57RF n naturalmente ser necesario realizar un autoaprendizaje en todos los CH173D no necesa...

Page 11: ...nos segundos se anulan todas las programaciones y se restablece el programa est ndar Teclas para la regulaci n de la temperatura m xima TMAX CONFORT desde 2 hasta 62 C AUTO Muncionamiento con el progr...

Page 12: ...en la pantalla comparecer la hora correspondiente 3 4 Una vez terminadas las modificaciones posicionar el desviador para encaminar la calefacci n o posicionar para el enfriamiento Con Intellitherm C57...

Page 13: ...eclas rojas se regula la temperatura de CONFORT T MAX a mantener en el ambiente Entonces los sectores rojos de la corona de la pantalla indican los per odos de encendido del sistema de climatizaci n e...

Page 14: ...indique que l autoapprentissage a effectivement t effectu N B Il est possible de commander deux ou plusieurs r cepteurs CH173D avec un seul C57RF naturellement il sera n cessaire d effectuer un autoap...

Page 15: ...t quelques secondes toutes les programmations s annulent et le programme standard se r tablie Touches de r glage de la temp rature maximale TMAX CONFORT de 2 62 C AUTO Fonctionnement avec programme au...

Page 16: ...e para tra l cran 3 4 A la fin des modifications positionner le commutateur pour mettre en marche le chauffage ou positionner le commutateur sur pour le refroidissement Avec C57RF il est possible d ex...

Page 17: ...de CLIMATISATION Avec les touches rouges on r gle la temp rature de CONFORT T MAX maintenir dans l ambiance Par cons quence les secteurs rouges de la couronne l cran indiquent les p riodes d allumage...

Page 18: ...uatoren CH173D mit nur einem C57RF zu steuern Nat rlich ist es notwendig das teach in bei allen CH173D auszuf hren nicht unbedingt im selben Moment UmdenBefestigungssockelvom vorderen K rper zu trenne...

Page 19: ...einige Sekunden lang gedr ckt werden alle Programmierungen gel scht und das Standardprogramm wiederhergestellt Tasten zur Einstellung der max Temperatur TMAX COMFORT von 2 bis 62 C AUTO Betrieb mit au...

Page 20: ...prechende Uhrzeit 3 4 Nach Beendigung der nderungen den Schalter auf positionieren um den Heizbetrieb einzuschalten oder auf um die K hlung einzuschalten Mit Intellitherm C57RF ist es m glich jederzei...

Page 21: ...eratur abzulesen MIN UND MA X R AUMTEM P E R ATU R AM V O R H E R G E H ENDEN TA G FORTGESCHRITTENE F UN K TIONEN B ET R IE B SSTUNDEN AUTO BETRIEBSSTUNDEN seit dem Start BETRIEBSSTUNDEN seit dem vorh...

Page 22: ...Intellitherm...

Page 23: ...ntegrados pueden desecharse con el producto stos ser n separados en los centros de reciclaje La barra negra indica que el producto se comercializ con posterioridad al 13 de agosto de 2005 Al participa...

Page 24: ...20090 Caleppio di Settala Milano ITALY Tel 39 02 956821 Fax 39 02 95307006 info fantinicosmi it SUPPORTO TECNICO Tel 39 02 95682225 supportotecnico fantinicosmi it EXPORT DEPARTMENT Ph 39 02 95682229...

Reviews: