background image

7

fantech

  Warranty

•  The maintenance free motors are 

permanently lubricated and are 
guaranteed for 7 years. They are 
factory balanced to prevent 
vibrations and promote silent 
operation.

• All other components have a 5 year 

limited warranty. (filters not included)

• The limited warranty covers normal 

use. It does not apply to any defects, 
malfunctions or failures as a result 
of improper installation, abuse, 
mishandling or misapplication, 
fortuitous occurrence or any other 
circumstances outside 
manufacturer's control.

• The warranty is in effect for 5 years 

on parts and 7 years on the motor 
after the date of purchase, including 
parts replaced during this time 
period. If there is no proof of 
purchase available, the date 
associated with the serial number 
will be used for the beginning of the 
warranty period. Parts are a 1 year 
warranty when replaced after the 
initial warranty has expired.

• This warranty is the exclusive and only 

warranty in effect and all other 
warranties either expressed or 
implied are invalid.

• Warranty from the manufacturer is 

for parts only and does not include 
labor or shipping to service or repair 
them.

Service

The useful service life of the filter media in the HEPA Filtration System is directly related to the 
volume of air passed through the system and the amount of contaminants in the air. In a typical 
residential application, Stage 1 and 2, filters should be replaced every three to six months or when 
needed. The Stage 3 HEPA filter should have a life span of two to five years, again, depending on  
the amount of particulate in the air and the maintenance of the Stage 1 pre-filter.
As an added service, Fantech offers an online filter replacement reminder service. Just go to 
www.fantech.net and for "Reminder Service" and follow the links. All you need to enter is your e-mail 
address, the product model and a description of the environment (Very Clean, Clean, Moderate).
The Service will send an e-mail after the elapsed time period when it is time to replace your filters.

Filter replacement

Stage 1   -   Prefilter: Air passes through the prefilter where larger particles are taken out of the 

air. (part number  40195, also available in packs of 24 part numer 40196)

Stage 2   -   Carbon: Air passes through the carbon filter where some gases and odors are 

removed. (part number  40195, also available in packs of 24 part numer 40196)

Stage 3   -   HEPA: Air passes through the certified HEPA media where very small particles are 

removed. 99.97% of all particles 0.3 microns and larger that pass through this stage 
are removed. Particles smaller than 0.3 microns are also removed with less intensity.

If the air flow through your unit is noticeably reduced, you can inspect the HEPA filter by removing it 
and seeing if the filter paper is darkened on the inlet or outer side. If it is, the filter cartridge should 
be replaced. (part number  40193, also available in packs of 12 part numer 40194)

Please contact your local Fantech dealer or call HEPA Customer Service at 1.800.565.3548 
regarding replacement of filter media, warranty information or if you have any questions or 
concerns about the performance of your HEPA Filtration System.

Replacement parts number for motor (410035) and for capacitor (410040).

Stage 1

Stage 3

Stage 2

Summary of Contents for HEPA DM 3000P

Page 1: ...n of the National Building Code and or ASHRAE s Good Engineering Practices Fantech reserves the right to modify at any time and without notice any or all of its products features designs components and specifications to maintain their technological leadership position Please visit our website www fantech net for more detailed technical information United States 10048 Industrial Blvd Lenexa KS 6621...

Page 2: ...fects Even reliable products will experience occasional failures and this possibility should be recognized by the user If these products are used in a life support ventilation system where failure could result in loss or injury the user should provide adequate back up ventilation supplementary natural ventilation or failure alarm system or acknowledge willingness to accept the risk of such loss or...

Page 3: ...3 fantech Table of content INTRODUCTION 4 SPECIFICATION 4 OPERATION 4 INSTALLATION 5 Installation instructions 5 TROUBLESHOOTING 6 SERVICE 7 FILTER REPLACEMENT 7 PARTS LIST 16 ...

Page 4: ...m in mm DM 3000P 16 406 20 508 10 1 2 268 Operation Your Fantech HEPA filtration system incorporates three stages of filtration Air is drawn from the house via one of the installation examples found in this manual by a powerful efficient EBM fan The air is cleaned as it passes through the filters where it is then reintroduced back into the home cleaned of the majority of harmful particles The DM30...

Page 5: ...lation or other obstacles Attach HEPA unit to mounting plate with screws Installing Grommet and Tubing First drill a 1 4 to 5 16 diameter hole in the duct wall on the supply air side of the furnace duct Carefully insert the grommet into the hole Drilling a metal duct may produce burrs Be careful not to cut or pricked by the burrs or the duct Make a mark a distance of1 2 from one end of the tubing ...

Page 6: ...the supply air duct If it reads less then 18 Pa 0 07 in wg the pressure switch will not work The only remedy is to set the rocker switch to CONTINUOUS Check this differential pressure on all available speeds of the forced air system B Problem When the DM3000P is on STANDBY it does not turn OFF 1 Other exhaust equipment in the house may interfere with the operation of the DM3000P by creating pressu...

Page 7: ...ain depending on the amount of particulate in the air and the maintenance of the Stage 1 pre filter As an added service Fantech offers an online filter replacement reminder service Just go to www fantech net and for Reminder Service and follow the links All you need to enter is your e mail address the product model and a description of the environment Very Clean Clean Moderate The Service will sen...

Page 8: ...8 fantech Notes ...

Page 9: ... bâtiment du Canada ou aux méthodes d ingénierie appropriées de l ASHRAE Fantech se réserve le droit de modifier partiellement ou entièrement en tout moment et sans préavis les caractéristiques la conception les composants et les spécifications de ses produits afin de conserver sa position de leader de technologie S il vous plaît visitez notre site siteweb www fantech net pour des informations tec...

Page 10: ...s pannes occasionnelles et cette possibilité devrait être reconnue par l utilisateur Si ces produits sont utilisés dans un système de ventilation qui maintien des fonctions vitales où une défaillance pourrait entraîner des pertes ou des blessures l utilisateur doit fournir une ventilation de secours adéquate une ventilation supplémentaire naturelle un système d alarme de défaillance ou d accepter ...

Page 11: ...11 fantech Table des matières INTRODUCTION 12 SPÉCIFICATION 12 OPÉRATION 12 INSTALLATION 13 Instructions d installation 13 DÉPANNAGE 14 SERVICE 15 CHANGEMENT DES FILTRES 15 LISTE DES COMPOSANTE 16 ...

Page 12: ...pi de Corde prise de 3 fourches Modèle A B C po mm po mm po mm DM 3000P 16 406 20 508 10 1 2 268 Opération Votre système de filtration HEPA de Fantech est un système de filtration à trois étages L air de la maison est aspiré voir les différents exemples d installation dans le présent manuel à l aide d un ventilateur EBM puissant et efficace L air passe dans les filtres pour y être épuré et est ens...

Page 13: ...ssion au conduit est correctement inséré dans le conduit d évacuation Le bout du tube devrait être libre d obstructions telle que de l isolant etc Attacher l unité HEPA avec les vis sur la plaque Installation du canon isolant et du tube Percez un trou de _ po à 5 16 po 6 35 à 7 94 mm dans le conduit sur le côté de l approvisionnement d air Insérez soigneusement le canon isolant dans le trou Attent...

Page 14: ...t inférieure à 18 Pa 0 07 po d eau le commutateur de différence de pression ne fonctionnera pas Il faudra alors placer l appareil on mode continue CONTINUOUS Vérifier cette différence de pression à toutes les vitesses disponibles sur le système de chauffage et ou de climatisation B Problème Quand le DM3000P est en mode d attente STANDBY le système ne s éteint jamais 1 Le fonctionnement de produits...

Page 15: ...nelle à la quantité d aérocontaminants et à l entretien du préfiltre de l étage 1 Comme un service supplémentaire Fantech offre un service en ligne de rappel de remplacement de filtre Allez juste à www fantech ca et pour le Reminder Service et suivez les liens Tout que vous devez entrer est votre adresse de E mail le modèle de produit et une description de l environnement très propre propre modéré...

Page 16: ...M3000P 40217 1 Duct Plate Adapter 401462 3 Motor Assembly 40323 4 Hepa Filter 40193 5 Pre Carbon Filter 40195 6 Capacitor 10uF 410040 7 Control Switch 410213 9 Latch 410312 Pressure Switch 411226 Hepa Filter Box of 12Pcs 40194 Pre Carbon Filter Box of 24Pcs 40196 ...

Page 17: ...17 fantech Notes ...

Page 18: ...18 fantech Notes ...

Page 19: ...19 fantech Notes ...

Page 20: ... to make technical changes For updated documentation please refer to www fantech net Fantech Fantech se réserve le droit de faire des changements tech niques Pour de la documentation à jour s il vous plaît se référer au www fantech net ...

Reviews: