background image

 

10

 

CONTROLS REFERENCE GUIDE 

Illusion, Mirage, Vision, Espirit 

(120VAC/240VAC Convertible pack)   

 

Initial Start-up 

When your spa is first actuated, it will go into priming mode, indicated by “Pr.” The Priming mode 

will last for less than 5 minutes and then the spa will begin to heat the spa and maintain the water temperature in the 
Standard mode.

 

 

Temperature Adjustment can only function between 80°F - 104°F / 26°C - 40°C

 

 

The start-up temperature is set at 100°F (37°C). The last measured temperature is constantly displayed on the LCD.  

Note: the last measured spa temperature displayed is current only when the pump has been running for at least 2 
minutes. 

 

To display the set temperature, press firmly on the Temp Up or Down pad once. Each time either pad is pressed again, the set 
temperature will increase or decrease depending on which pad is pressed. After three seconds, the LCD will automatically display the 
last measured spa temperature

Jets 

 

Firmly press the “Jets” button once to activate the low speed of the pump and again for the high speed. Firmly press the “Jets” 
button again to turn off the pump. If left running, the low speed of the pump will automatically turn off after 4 hours, and the 
high speed will automatically turn off after 15 minutes. The low speed of the pump may also activate for at least 2 minutes 
every 30 minutes to detect the spa temperature and then to heat to the set temperature if needed, depending upon mode. When 
the low speed turns on automatically, it cannot be deactivated from the panel; however, the high speed may be started. 

   Light 

 

   Firmly press the “Light” button to turn the light on and off. If left on, the light automatically turns off after 4 hours.                       

Operational Mode:                                                                                                                                                                        

The default operational mode is preset from the factory for Standard Mode. In order to be programmed into either alternative 
Economy or Sleep modes as described below dip switch #7 on the power supply board must be moved downward into the “off” 
position as described on Page 9.                                                                                             

                                                                                  

Mode 

 

Mode is changed by pressing the Temp Up orDown button, then pressing the ‘light” button. 
 

Standard Mode

 

is programmed to maintain the desired temperature.  Note the last measured spa temperature displayed is 

current only when the pump has been running for at least 2 minutes.                                                                                              

“St”

 

will be displayed momentarily when you switch into Standard mode.                                                                     

Economy Mode

 heats the spa to the set temperature only during filter cycles. 

“Ec”

 

will display solid when temperature is not current, and will alternate with temperature when temperature is current. 

Sleep Mode

 heats the spa to within 20º F (6.6º C) of the set temperature only during filter cycles. 

“SL”

 

will display solid when temperature is not current, and will alternate with temperature when temperature is current

 

Summary of Contents for ILLUSION

Page 1: ...www fantasyspas com OWNER S MANUAL November 1 2007 ILLUSION MIRAGE VISION ESPIRIT...

Page 2: ...ns 14 Fill Up and Start Instructions 15 Adding Start Up Chemicals 16 Cleaning or Winterizing 17 Spa Maintenance 18 19 Troubleshooting Procedures 20 Limited Warranty Fantasy Series 21 Most cities count...

Page 3: ...igned to provide you with the information you will need to ensure the safe secure use of your new hot tub IMPORTANT Freeflow Products Incorporated reserves the right to change specifications or design...

Page 4: ...stallations require adequate ventilation When the hot tub is in use considerable amounts of moisture are produced This moisture can damage walls and ceiling surfaces over time Special paint is availab...

Page 5: ...TRACTOR PREPARE THE FOUNDATION FOR YOUR HOT TUB There is a 4 10cm minimum depth requirement for a concrete pad Placing the Hot Tub CHECK THE DIMENSIONS OF YOUR HOT TUB Compare the hot tub dimensions t...

Page 6: ...ion within 5 feet 1 5m of the hot tub 7 WARNING To reduce the risk of Injury a Before using your hot tub you should measure the water temperature with an accurate thermometer since the tolerance of wa...

Page 7: ...for extended use exceeding 10 to 15 minutes and for young children 7 Since excessive water temperature has a high potential for causing fetal damage during the early months of pregnancy pregnant or po...

Page 8: ...e must be provided that is as large as the largest current carrying conductor but no less than 8 AWG 8 4mm2 Use copper wiring only 7 Please open the front cover of the power pack and follow the instru...

Page 9: ...1 low operation When configured to operate at 240V the heater is rated at 4 0kW and will heat whenever heat is required Printed Circuit Board Layout 120V Input Voltage WHT BLK GRN WHT BLK RED GRN Jum...

Page 10: ...e pump may also activate for at least 2 minutes every 30 minutes to detect the spa temperature and then to heat to the set temperature if needed depending upon mode When the low speed turns on automat...

Page 11: ...for details Diagnostic Messages Overheat condition OH WARNING DO NOT ENTER HOT TUB Water is too hot Overheat protection Heater is deactivated Spa water temperature is above acceptable limits When the...

Page 12: ...een running for 2 minutes the temperature will be displayed DO NOT ENTER THE WATER Remove the spa cover and allow water to cool Once the heater has cooled reset by pushing any button If spa does not r...

Page 13: ...pack will turn on the heating element for whatever duration is necessary In the case of a heat recovery pack the motor will run producing heat for your hot tub water until it reaches temperature 3 Dep...

Page 14: ...low speed the water movement through the ozone jet draws the ozone out of the compartment mixes with and purifies the water in the process WHIRLPOOL JET when equipped If your hot tub is installed with...

Page 15: ...the main power panel to be sure you have the correct voltage for the Power System being used Also be sure the voltage is within or 10 of the mean voltage For 120 VAC it should be between 108 VAC and...

Page 16: ...t of balance A measurement below 7 2 indicates that your water is more acidic This water condition results in corrosion of the equipment s metal components A measurement above 7 8 indicates that your...

Page 17: ...the Start up Instructions to refill your spa Before draining power must be turned off at the GFCI circuit breaker Within the equipment compartment locate the drain hose bib Attach a garden hose to the...

Page 18: ...ose Rotate and separate filter pleats while spraying water to remove all dirt and debris possible Let filter dry and look for calcium deposits scaling or an oil film If you find these you will need to...

Page 19: ...bulb must be the same rating as the factory installed bulb Check with your dealer or Fantasy for the correct replacement part SHELL COLOR AND APPEARANCE Your hot tub shell has been designed to have t...

Page 20: ...e the water level is at the texture line 4 Check for dirty filter Clean if necessary 5 Make sure all jets are in the open position WATER IS TOO HOT 1 Check desired temperature on topside control 2 Che...

Page 21: ...necessary repair of the defect Freeflow Spas Inc will then ship the hot tub back to you pre paid Freeflow Spas Inc pays upon completion of the repair Freeflow Products Inc must be contacted in advance...

Reviews: