background image

LIMITED  LIFETIME  MOTOR  WARRANTY  -  If any  part  of  your  fan  motor  fails,  due  to  a  defect  in  materials  or  workmanship  during 

1.

the lifetime of the original purchaser, Fanimation will provide the replacement part free of charge, when the defective fan is returned 
to our national service center.  Proof of purchase is required.  Customer shall be responsible for all costs incurred in the removal or 
reinstallation and shipping of the product for repairs or replacement.

ONE YEAR MOTOR LABOR WARRANTY - If your fan motor fails at any time within one year from the original purchase, due to defects 

2.

in materials or workmanship, labor to repair the motor will be provided free of charge at our national service center.  Purchaser will 
be responsible for labor charges after this one-year period.  Customer shall be responsible for all costs incurred in the removal or 
reinstallation and shipping of the product for repairs or replacement.

If any other part of your fan fails at any time within one year after original purchase, due to a defect in materials or workmanship, we will 

3.

repair, or replace, at our option, the defective part free of charge for parts and labor performed at our national service center.

Because of varying climate conditions, this warranty does not cover changes in the finish, including rusting, pitting, corroding, tarnishing, 

4.

or peeling.

This warranty is void and does not apply to damage from improper installation, neglect, accident, misuse, exposure to extremes of heat 

5.

or humidity, or as a result of any modification to the original product.

All costs of removal and reinstallation of the fan are the sole responsibility of the owner of the fan and not the store that sold the fan 

6.

or Fanimation.

Fanimation reserves the right to modify or discontinue any product at any time and may substitute any part under this warranty.

7.

Under no circumstances may a fan be returned without prior authorization from Fanimation.  The receipt of purchase must accompany 

8.

authorized returns and must be sent freight prepaid to Fanimation.  The fan to be returned must be properly packed to avoid damage 
in transit; Fanimation will not be responsible for any damage resulting from improper packaging.

It is understood that any repair or replacement is the exclusive remedy available from Fanimation.  There is no other expressed or 

9.

implied warranty.  Fanimation hereby disclaims any and all implied warranties, including, but not limited to those of merchantability and 
fitness for a particular purpose to the extent permitted by law.  Some states do not allow limitations on implied warranties.  Fanimation 
will not be liable for incidental, consequential, or special damages arising out of or in conjunction with product use or performance, 
except as may otherwise be accorded by law.  This warranty gives you special legal rights and you may also have other rights that 
vary from state to state.

A certain amount of wobble is normal and should not be considered a problem or a defect.

10.

LIMITED LIFETIME WARRANTY

Extends to the original purchaser of a Fanimation Fan

Important Safety Instructions

WARNING: To avoid fire, shock and serious personal injury, follow these instructions.

Table of Contents

Unpacking Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Energy Efficient Use of Ceiling Fans

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Electrical and Structural Requirements

. . . . . . . . . . . . . . . . . . . . . . . . . . 4

How to 

Assemble

 Y

our Ceiling Fan

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

How to Hang Y

our Ceiling Fan with Downrod

. . . . . . . . . . . . . . . . . . . . . 8

How to Wire Y

our Ceiling Fan

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

Installing the Canopy Housing

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

How to 

Assemble the Blades

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Housing/Switch Cup Assembly

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

Maintenance

11

Blade Cleaning

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  11

Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .12

Exploded-

V

iew Drawing

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

T

rouble Shooting

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

Read your owner’s manual and safety information before installing your new fan.  Review the accompanying assembly diagrams.

1.

Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power 

2.

from being switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a warning device, 
such as a tag, to the service panel.
Be careful of the fan and blades when cleaning, painting, or working near the fan.  Always turn off the power to the ceiling fan 

3.

before servicing.
Do not insert anything into the fan blades while the fan is operating.

4.

Do not operate reversing switch until fan blades have come to a complete stop.

5.

Additional Safety Instructions

To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.

1.

All wiring and installation procedures must satisfy National Electrical Codes (ANSI/ NFPA 70-1999) and Local Codes.  The ceiling fan 

2.

must be grounded as a precaution against possible electrical shock.  Electrical installation should be made or approved by a licensed 
electrician.
The fan base must be securely mounted and capable of reliably supporting at least 35 lbs.  See page 4 of owner’s manual for support 

3.

requirements.  Consult a qualified electrician if in doubt.
The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.

4.

Follow  the  recommended  instructions  for  the  proper  method  of  wiring  your  ceiling  fan.    If  you  do  not  have  adequate  electrical 

5.

Use only with light kits marked suitable for use in damp locations.

6.

knowledge or experience, have your fan installed by licensed electrician.

W

ARNING:

  This product is designed to use only those parts supplied with this product and/or accessories designated specifically for 

use with this product.  Using parts and/or accessories not designated for use with this product could result in personal injury or property 
damage.

W

ARNING:

  To reduce the risk of personal injury, do not bend the blade bracket (flange or blade holder) when installing the brackets, 

balancing the blades, or cleaning the fan.  Do not insert foreign objects in between rotating fan blades.

W

ARNING:

  To Reduce The Risk Of Fire Or Electric Shock.  Do Not Use This Fan With Any Solid-State Speed Control Device.

W

ARNING:

  To Reduce The Risk Of  Electric Shock.  Disconnect The Electrical Supply Circuit To The Fan Before Installing Light Kit.

Summary of Contents for CANCUN FP8042 SERIES

Page 1: ...OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Model Nos FP8042 The Cancun 42 Ceiling Fans Net Weight 6 97 kg 15 37 lbs...

Page 2: ...considered a problem or a defect 10 LIMITED LIFETIME WARRANTY Extends to the original purchaser of a Fanimation Fan Important Safety Instructions WARNING To avoid fire shock and serious personal inju...

Page 3: ...ver Assembly Blade Holder Set Blade Set One Phillips head screwdriver One stepladder One blade screwdriver One wire stripper Three wire connectors supplied Hardware bags Eleven 1 4 20 x 14 screws with...

Page 4: ...need to be replaced Consult a qualified electrician if in doubt Energy Ef cient Use of Ceiling Fans Ceiling fan performance and energy savings rely heavily on the proper installation and use of the c...

Page 5: ...e holes in the downrod support with holes in the downrod Se cure clevis pin with hairpin clip Tighten the two set screws with nuts in the downrod support Figure 3 Black Blue and White Leads Figure 2 S...

Page 6: ...in the motor coupler Firmly attach the canopy cover to the motor with the three screws removed in step1 Figure 3 How to Assemble Your Ceiling Fan Close to Ceiling NOTE All set screws must be checked a...

Page 7: ...he keyed portion of the slot Tighten the screws Figure 7 How to Assemble Your Ceiling Fan Close to Ceiling Cont d Figure 5 Figure 7 Figure 8 Figure 9 Figure 6 OUTLET BOX HOOK HANGER BRACKET MOTOR ASSE...

Page 8: ...nger bracket must seat rmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or...

Page 9: ...e Wire from Supply Figure 13 3 After splicing and making the wire connections the wires should be spread apart and turned upward with the grounded conductor and the equipment grounding conductor on on...

Page 10: ...Phillips screwdriver tighten 3 16 24x7 5 mm washer head screws with ber washers to secure the blade to the blade arm Figure 19 HARDWARE USED 3 16 24 x 7 5 mm WASHER HEAD SCREWS X 15 FIBER WASHER X 15...

Page 11: ...rags which can warp and ruin the blades Housing Switch Cup Assembly 1 4 Assemble the switch cup assembly onto the assembled adapter with three screws Figure 24 Disassemble the housing switch cup assem...

Page 12: ...y 11 Hardware Bag APGAC111BL ADRAC1 45 APPAC1081 PPAC1003 APPAC1102 AP1115 AMA8042 AP804201 AP804202 AP804203 HDWFP8042 Loose Hardware Bag Blade Balance Kit Chain Coupler Chain Fob Wire Connectors 4 B...

Page 13: ...13 FP8042 Exploded View NOTE The illustration shown is not to scale or its actual configuration may vary 1 2 3 4 5 6 7 10 11 9 8...

Page 14: ...other or against the interior wall of the switch housing CAUTION Make sure main power is turned off 5 Some fan motors are sensitive to signals from solid state variable speed controls Solid state cont...

Page 15: ...Copyright 2010 Fanimation 2010 11 10983 Bennett Parkway Zionsville IN 46077 Toll Free 888 567 2055 FAX 866 482 5215 Outside U S call 317 733 4113 Visit Our Website www fanimation com...

Page 16: ...The Cancun 42 Ventilador de techo Peso neto 6 97 kg 15 37 lb MANUAL DEL PROPIETARIO LEA Y GUARDE ESTAS INSTRUCCIONES Modelo N FP8042...

Page 17: ...nuevo ventilador Observe los diagramas de 1 ensamblaje adjuntos Antes de llevar a cabo el mantenimiento o la limpieza de la unidad desconecte la electricidad en el panel de servicio y bloquee los 2 m...

Page 18: ...rate a un electricista autorizado para instalar el ventilador La caja de distribuci n el ctrica y los conectores de la caja deben ser del tipo requerido por el c digo local El cable m s peque o debe s...

Page 19: ...s consumen menos energ a En invierno Invierta el motor y haga funcionar el ventilador de techo a velocidad baja y en el sentido de las agujas del reloj Esto produce una suave corriente ascendente que...

Page 20: ...Asegure con dos tuercas los dos tornillos del soporte de la barra vertical Figura 3 Figura 2 Figura 3 Unidad de la cubierta circular estilizada Unidad de la cubierta circular estilizada Figura 4 Figur...

Page 21: ...e han omitido de esquema NOTA Cables del motor se han omitido de esquema NOTA Cables del motor se han omitido de esquema Figura 2 Escudo del techo Unidad de la cubierta circular estilizada Ensamble de...

Page 22: ...n la parte correcta de la ranura A continuaci n fije adecuadamente los tornillos Figura 7 Figura 5 Figura 7 Figura 8 Figura 9 Figura 6 gancho Ranura Ranura Surco Pesta as de montaje 4 7 Instale los do...

Page 23: ...rese de cortar la alimentaci n el ctrica de la caja de fusibles principal antes de colgar el ventilador Debe colgar el ventilador a una distancia m nima de 2 13 m desde las aspas hasta el piso Figura...

Page 24: ...ja de distribuci n el ctrica y el conductor sin conexi n a tierra debe ir del otro lado Figura 13 Verifique que todas las conexiones est n ajustadas incluida la conexi n a tierra y que no haya conduct...

Page 25: ...colocadas podr a ocasionar da os en las mismas PRECAUCI N 2 Coloque el aspa sobre el soporte de aspas con los pilotes roscados a la vista Aseg rese de que la parte inferior del aspa se encuentre bien...

Page 26: ...redonda del interruptor Unidad redonda del interruptor 3 Fije adecuadamente el conector redondo del interruptor de 9 clavijas en la conexi n del arn s del cableado ubicado en la unidad del motor Figur...

Page 27: ...de techo 5 Cubierta para el tornillo del 6 Cubierta de uni n del motor 7 Unidad del motor del ventilador 8 Soporte de aspa de set 9 Aspa de set 10 Unidad redonda del interruptor 11 Bolsa de accesorio...

Page 28: ...29 FP8042 1 2 3 4 5 6 7 10 11 9 8 Despiece NOTA la ilustraci n que se muestra no est hecha a escala y su con guraci n real puede variar...

Page 29: ...los tornillos de fijaci n 3 EL VENTILADOR OSCILA EN EXCESO 1 El tornillo de fijaci n y la tuerca del soporte de barral est n flojos 2 El tornillo de fijaci n en la unidad del barral de la semiesfera e...

Page 30: ...2010 Fanimation 2010 11 10983 Bennett Parkway Zionsville IN 46077 Llame Sin Cargo al 888 567 2055 FAX 866 482 5215 Desde fuera de los EE UU llame al 317 733 4113 Visite nuestro sitio Web en www fanim...

Reviews:

Related manuals for CANCUN FP8042 SERIES