background image

Wiring diagram

DC 14,5V

power supply

DC 14,5V

power supply

DC 14,5V

power supply

DC 14,5V

power supply

4p

4p

4p

4p

4p

4p

4p

4p

DC12V
power supply

DC12V
power supply

22

Door
station 1

Door
station 2

Bolt

Bolt

 
1. 

Before installing and operating this video door phone set, you should carefully read 

    

the following instructions. Improper connection and damages caused by it are not covered 

    

by the warranty.

2. When connecting the power supply to the video door phone, pay special attention 

    

to the correct connection of the power supply polarity!

    

Incorrect connection will damage the video door phone!

3. For installation up to 30 m use cables with a minimum diameter of 0.50 mm; for instal

-

    

lation of more than 30 m - min. 0.70 mm. 

    

For the best image quality in video line, we recommend use of a 75 

Ω

 coaxial cable.

4. ZV-14 power supply is recommended to power the bolt

.

27

Summary of Contents for KK-01B

Page 1: ...User guide Video door phones RoHS ...

Page 2: ... monitors 12 Description of the symbols in the diagrams monitors 21 Installation 26 27 Wiring diagram of CCTV camera 41 Operating the video door phone 42 Warranty card 45 Programming of the door station with combination lock 8 Programming of the door station with card reader 10 Operating the monitor with memory 23 Wiring diagram ...

Page 3: ... 75 182 60 mm KK 03 1 audio red 2 ground blue 3 camera power supply from the monitor yellow 4 video white 5 additional bolt release button 6 DC12 14 5V power supply bolt bolt switch 7 do not connect power supply FF ZV 14 access block for users 10 20 and 36 40 8 bolt 9 DC12 14 5V power supply 10 DC12V power supply _ Monitor Volume control 5 6 7 8 9 10 red blue yellow white Bolt release button EXIT ...

Page 4: ...rol Dimensions 120 250 51 mm Installation box dimensions 110 240 46 mm KK 05 1 audio red 2 ground blue 3 camera power supply from the monitor yellow 4 video white 5 DC12 14 5V power supply black power supply FF ZV 14 bolt 6 bolt 8 DC12 14 5V power supply red 9 Bolt Monitor 6 Volume control Power supply 8 9 Bolt release button EXIT Access block button for users 10 20 and 36 40 4 2 3 4 5 6 7 2 3 4 5...

Page 5: ... supply black power supply FF ZV 14 bolt 6 bolt 8 DC12 14 5V power supply red 9 KK 08K Dimensions 120 250 51 mm Installation box dimensions 110 240 46 mm Please note Remove the jumper J3 in all monitors and uniphones 1 audio red 2 ground blue 3 camera power supply from the monitor yellow 4 video white 5 bolt DC12 14 5V power supply black power supply FF ZV 14 6 bolt 8 DC12 14 5V power supply red 9...

Page 6: ...ve jumper J3 in all monitors and uniphones Bolt 6 Volume control Power supply 8 9 Monitors 1 audio red 2 ground blue 3 camera power supply from the monitor yellow 4 video white 5 DC12 14 5V black FF ZV 14 bolt 6 bolt 8 DC12 14 5V power supply red 9 power supply power supply 6 2 3 4 5 6 7 8 ...

Page 7: ...t 70 adjustable Operating temperature range Minimum illumination 0 05 Lux Converter 1 3 CCD IP 55 Backlight LED 25 C 55 C Protection cowl LED Camera Speaker Call button Microphone Camera mounting screw Signboard for name Keyboard Cable ducting LED indicating operating status of the keypad Card reader Function description No Description of the symbols in the diagrams door stations 1 2 3 4 5 6 7 8 9...

Page 8: ...d press you will hear three short beeps e return to step 3 in case of removing more user codes or press to complete the removal after pressing you will hear five short beeps 3 Programming the lock opening time a press you will hear two short beeps b enter the administrator code you will hear three short beeps red LED will begin to flash c enter you will hear two short beeps d enter the required op...

Page 9: ...ll hear two short beeps b enter administrator code you will hear three short beeps red LED will begin to flash c press you will hear two short beeps the LED flashes d press you will hear two short beeps the LED flashes e press successively six times you will hear one short beep the LED flashes f press you will hear five short beeps the LED goes out the system reset ...

Page 10: ...e its color from red to orange b exit the programming mode by pressing the the tone and LED color change to red will confirm a return to operating mode 3 Adding user card a Enter the programming mode see point 1 b Press number on the remote control you will hear a long beep c Enter the last 6 digits of the card number or bring it closer to the reader short beep means the card was accepted the next...

Page 11: ...you will hear one short and one long beep confirming your card has been saved in the memory 4 To exit card adding mode press you will hear a long beep and the LED will change its color to red the device is ready to work 5 MASTER cards cannot be removed only new card can be programmed in place of damaged or lost card 8 Restoring the forgotten administrator code 1 Turn off power supply for at least ...

Page 12: ...off J2 fit the cable in the video line a jumper put on coaxial cable if the system has more than one monitor installed leave only the jumper in the last monitor and remove it in all the other monitors b jumper removed other cable J3 switching on or off the backlight of the call button and the signboard in KK 04 door station a jumper put on backlight on b jumper removed backlight off In case of doo...

Page 13: ...oor station a jumper put on backlight on b jumper removed backlight off In case of door stations other than KK 04 the jumper must be removed 1 audio red 2 ground blue 3 camera power supply yellow 4 video white 8 of power supply red 9 of power supply black 10 connection to the control input of the door automaton it is a closing contact of the NO relay dry contact Do not connect voltages greater tha...

Page 14: ...ight on b jumper removed backlight off In case of door stations other than KK 04 the jumper must be removed MK 06B 1 audio red 2 ground blue 3 camera power supply yellow 4 video white 8 of power supply red 9 of power supply black 10 connection to the control input of the door automaton it is a closing contact of the NO relay dry contact Do not connect voltages greater than 24 V the current should ...

Page 15: ...station a jumper put on backlight on b jumper removed backlight off In case of door stations other than KK 04 the jumper must be removed 1 audio red 2 ground blue 3 camera power supply yellow 4 video white 8 of power supply red 9 of power supply black 10 connection to the control input of the door automaton it is a closing contact of the NO relay dry contact Do not connect voltages greater than 24...

Page 16: ... removed chime off J2 fit the cable in the video line a jumper put on coaxial cable if the system has more than one monitor installed leave only the jumper in the last monitor and remove it in all the other monitors b jumper removed other cable J3 switching on or off the backlight of the call button and the signboard in KK 04 door station a jumper put on backlight on b jumper removed backlight off...

Page 17: ...m a 1 monitor jumper put on resistor on the cables between video and ground b 2 monitors jumpers in two monitors put on c 3 monitors jumper removed in first monitor put on in monitors 2 and 3 d 4 monitors jumper removed in first and second monitor put on in 3 and 4 J3 switching on or off the backlight of the call button and the signboard in KK 04 door station a jumper put on backlight on b jumper ...

Page 18: ...has more than one monitor installed leave only the jumper in the last monitor and remove it in all the other monitors b jumper removed other cable J3 switching on or off the backlight of the call button and the signboard in KK 04 door station a jumper put on backlight on b jumper removed backlight off In case of door stations other than KK 04 the jumper must be removed connection of the DC 14 5 V ...

Page 19: ... b jumper removed backlight off In case of door stations other than KK 04 the jumper must be removed Save photo button Preview photo button Navigation cursors 1 audio red 2 ground blue 3 camera power supply yellow 4 video white 8 of power supply red 9 of power supply black 10 connection to the control input of the door automaton it is a closing contact of the NO relay dry contact Do not connect vo...

Page 20: ...it in all the other monitors b jumper removed other cable J3 switching on or off the backlight of the call button and the signboard in KK 04 door station a jumper put on backlight on b jumper removed backlight off In case of door stations other than KK 04 the jumper must be removed 1 audio red 2 ground blue 3 camera power supply yellow 4 video white 8 of power supply red 9 of power supply black ea...

Page 21: ...all volume adjusting Color adjusting Ringer volume adjusting DC 14 5V During operation 7W 10 LCD 7 LCD 4 LCD Technical data Power supply Power consumption Screen Operating temperature range 10 C 55 C Description of the symbols in the diagrams monitors MK 03G black MK 03W white MK 04W MK 04B MK 06B MK 06WF MK 07WB MK 09W MU 01 MU 02 Function description No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 ...

Page 22: ...automaton control Brightness adjusting Call volume adjusting Color adjusting Ringer volume adjusting DC 14 5V During operation 7W 10 LCD 7 LCD 4 LCD Technical data Power supply Power consumption Screen Operating temperature range 10 C 55 C MK 08F MK 10F Menu exit Navigation cursor UP Menu Navigation cursor DOWN Browse photos 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ...

Page 23: ...ting photos Pressing the button opens the menu window By pressing the button the appro priate number of times we go to the window Remove all pressing the or arrow will erase all photos from memory To exit this menu press button or wait 10 seconds without executing any other operation Adjusting display settings brightness contrast color saturation Pressing the button opens the menu window By pressi...

Page 24: ...e With or arrow or you can browse the previous or next photos in full size or by pressing the button return to the thumbnail preview If no button is pressed for 10 seconds the monitor automatically returns to standby mode Deleting individual photos To delete the photos you need to enter the thumbnail preview mode We choose the desired thumbnail by highlighting it and by pressing the button we dele...

Page 25: ...ays the date and time in format yyyy mm dd hh mm The corresponding values in the flashing fields are set with or arrows Settings are confirmed by pressing button the device automatically switches to set the following values of the current month day of the week hour and minutes After the minutes setting and the confirmation with button the monitor switches to standby mode ...

Page 26: ...licone 3 Do not install the unit in areas exposed to vibration or shock 1 Choose a place to install the monitor 2 Attach the wall mount for the monitor installation optimum height to place the monitor is 155 170 cm 3 Connect the camera wires to the monitor 4 Attach the monitor to the mount 5 Connect the monitor power supply Installation 26 ...

Page 27: ...roper connection and damages caused by it are not covered by the warranty 2 When connecting the power supply to the video door phone pay special attention to the correct connection of the power supply polarity Incorrect connection will damage the video door phone 3 For installation up to 30 m use cables with a minimum diameter of 0 50 mm for instal lation of more than 30 m min 0 70 mm For the best...

Page 28: ...onitors or uniphones white blue red yellow Monitor 1 Monitor 2 DC14 5V power supply DC14 5V power supply white blue red yellow Door station 1 Monitor 1 DC14 5V power supply ZV 14 power supply red black red black red black Bolt Bolt ZV 14 power supply Door station 1 28 ...

Page 29: ... station 1 monitor or uniphone Monitor 1 DC14 5V power supply white blue red yellow Door station 1 ZV 14 power supply ZV 14 power supply red black white blue red yellow Bolt Bolt Door station 2 KK 01 KK 04 29 ...

Page 30: ... uniphones KK 01 KK 04 Monitor 1 DC14 5V power supply Monitor 2 DC14 5V power supply white blue red yellow Door station 1 ZV 14 power supply ZV 14 power supply red black red black white blue red yellow Bolt Bolt Door station 2 30 ...

Page 31: ...V 14 power supply Monitor 1 DC14 5V power supply red black white blue red yellow 1 door station 2 monitors or uniphones DC14 5V power supply Door station 1 DC14 5V power supply red black red black white blue red yellow Bolt Bolt release button ZV 14 power supply Monitor 1 Monitor 2 31 ...

Page 32: ...monitor or uniphone Monitor 1 DC14 5V power supply white blue red yellow Door station 2 white blue red yellow Door station 1 red black Bolt Bolt release button ZV 14 power supply Bolt Bolt release button ZV 14 power supply 32 ...

Page 33: ... Monitor 1 Door station 1 Door station 2 DC14 5V power supply Monitor 2 DC14 5V power supply red black red black white blue red yellow white blue red yellow Bolt Bolt release button ZV 14 power supply Bolt Bolt release button ZV 14 power supply 33 ...

Page 34: ...t ZV 14 power supply Monitor 1 DC14 5V power supply red black white blue red yellow 1 door station 2 monitors or uniphones DC14 5V power supply DC14 5V power supply red black red black Monitor 1 Monitor 2 Door station 1 Bolt ZV 14 power supply white blue red yellow ...

Page 35: ...K 05 2 door stations 1 monitor or uniphone Monitor 1 DC14 5V power supply white blue red yellow white blue red yellow red black Door station 1 Bolt ZV 14 power supply Door station 1 Bolt ZV 14 power supply ...

Page 36: ...tors or uniphones KK 05 Monitor 1 DC14 5V power supply Monitor 2 DC14 5V power supply red black red black white blue red yellow white blue red yellow Door station 1 Bolt ZV 14 power supply Door station 1 Bolt ZV 14 power supply ...

Page 37: ... door station 2 monitors or uniphones Door station 1 Bolt ZV 14 power supply black Monitor 2 DC14 5V power supply red white blue red yellow Monitor 1 DC14 5V power supply white blue red yellow 37 black red black red ...

Page 38: ...tion 1 Bolt ZV 14 power supply black Monitor 2 DC14 5V power supply red white blue red yellow Monitor 1 DC14 5V power supply white blue red yellow red black Bolt ZV 14 power supply black red red blue yellow white white yellow blue red Door station 2 38 black red ...

Page 39: ... red yellow Monitor 1b DC14 5V power supply red blue white yellow DC14 5V power supply ZV 14 power supply white blue red yellow Monitor 2a white blue red yellow Monitor 2b DC14 5V power supply DC14 5V power supply KK 08 KK 08K 39 red black red black red black red black red black ...

Page 40: ...hite blue red yellow Monitor 4 DC14 5V power supply white blue red yellow Monitor 6 DC14 5V power supply white blue red yellow Monitor 8 DC14 5V power supply white blue red yellow ZV 14 power supply Bolt DC12V 40 red black red black red black red black ...

Page 41: ...ect any CCTV camera instead of a camera in the door station Monitor Door station CCTV camera Power supply Instead of a second door station you can install any CCTV camera yellow black red white yellow blue red white blue red yellow blue red white black Wiring diagram of CCTV camera 41 ...

Page 42: ... to open the door press the door release button 1 Guest presses the call button on the camera 1 If you want to observe the surroundings located in front of the camera on the monitor press the preview button 2 If two cameras are installed in the system a press the button once turn on the camera1 b press the button for a second time turn on the camera 2 c press the button for a third time the monito...

Page 43: ...installed in the system to call a second monitor press the intercom button The call signal will ring on the second moni tor screen will remain blank a to establish communication with the first monitor press the button of call receiving b to end the call press the button again 43 ...

Page 44: ... collected separately and sorter in order to optimize recovery and recycling of certain components and materials This allows reducing environ mental pollution and has a positive impact on the human health Crossed trashcan sign on the product reminds the client of his obligation of a special sorting Consumers should contact with local authorities or retailer for information on dealing with used ele...

Page 45: ...tions excessive humidity too high or too low temperature sunshine etc different conditions for main tenance and operation than those that can be found in the operating manual of the product mechanical chemical thermal damage damage caused by external forces such as surges on the electricity network lightning flood fire damage caused by improper installation of equipment improper storage of equipme...

Page 46: ...Product name Type Data of sale Stamp and signature of the seller Date of repair Repairs registration Scope of repair Signature of techincian 46 ...

Page 47: ...Date of repair Repairs registration continued Scope of repair Signature of technician 47 ...

Page 48: ...F F Filipowski Sp j Konstantynowska 79 81 95 200 Pabianice phone 48 42 215 23 83 48 42 227 09 71 e mail handlowy fif com pl www fif com pl ...

Reviews: