![F&F KK-01B User Manual Download Page 12](http://html.mh-extra.com/html/fandf/kk-01b/kk-01b_user-manual_534595012.webp)
12
Description of monitors
Dimensions: 241×161×23 mm
MK-03G (black), MK-03W (white)
1) audio-red
2) ground-blue
3) camera power supply-yellow
4) video-white
8) (+) of power supply-red
9) (-) of power supply-black
10
)
connection to the control input of the door
automaton, it is a closing contact
of the NO relay (dry contact).
Do not connect voltages greater than 24 V,
the current should not exceed
150 mA
.
J1, J2, J3 jumper configuration:
J1: switching on or off the chime in the door station
a)
jumper put on – audible chime
b)
jumper removed – chime off
J2: fit the cable in the video line
a)
jumper put on – coaxial cable, if the system has more than one monitor installed,
leave only the jumper in the last monitor and remove it in all the other monitors
b)
jumper removed – other cable
J3: switching on or off the backlight of the call button and the signboard in KK-04 door
station:
a)
jumper put on – backlight on
b)
jumper removed – backlight off
In case of door stations other than KK-04,
the jumper must be removed
.
1
0
1
0
1
2
3
4
1
2
3
4
8
9
J3
J2
J1
POW
connection
of the door
station
2
connection
of the DC 14.5 V
power supply
connection
to the control input
of the door automaton
10 10
1
2
3
4
1
2
3
4
8
9
J3
J2
J1
POW
connection
of the door
station 1
1
2
3
4
5
15
14
8
9
10
11