Lumina 38
Inputs and outputs
55
Type
Setting of the type of measurement being carried out:
•
NONE
•
TEMPERATURE
•
CO2 3000 PP
•
CO2 30000 PP
•
LINEAR (U)
•
LINEAR (R)
•
POLYNOMIAL (U)
•
LUX (R)
Measurement
The measured signal (if changed manually, the correction value is adjusted
accordingly).
Correction
Readout of the correction of the measurement (this value can only be reset).
Digital inputs have the following settings:
Input address
The address of the analog input.
Type
Setting of the type of measurement being carried out.
•
NONE
•
LEVEL
•
COUNT
•
FREQ
•
DSR feedback
Analog outputs have the following settings:
Output address
The address of the output.
Channel type
Shows the type of analog output.
Channel function
Setting of the type of analog control (
0
– 10V
/
10
– 0V
).
Correction factor
Factor to determine the adjustment of the setpoint. This damps the effect of the control.
Repeat time
The minimum time between two adjustments in the control by the computer control. This
setting means the control computer will not change the degree of control too quickly.
Max. buffer
The control computer repeatedly determines the difference between the actual control
value and the required setpoint. It places these difference values in a buffer, until the
Max. buffer
is reached.
The adjustment to the setpoint is the average of the values in the buffer. The control
computer can correct the adjustment using the
Correction factor
.