Lumina 16
House setup
30
HOUSE SETUP
tab page
User
Apply temperature curve
Setting indicating if the house temperature is to be controlled based on the curve.
Apply ventilation curve
Setting indicating if the minimum and maximum ventilation levels are to be controlled
based on the curve.
Apply water-feed curve
Setting indicating if the feed and water supplies are to be controlled based on the curve.
Fancom HumiTemp
Setting indicating if HumiTemp is to be used to correct the house temperature.
Data linked to animals
Setting indicating that clocks are only to be controlled if there are animals in the house.
The control computer will also calculate the feed and water amounts based on the
number of set up animals.
Ventilation standard
Setting used to determine how the minimum ventilation standard is entered:
As a percentage, irrespective of the number of animals.
Per animal (
m3/h/animal
).
Per kilo animal weight (
m3/h/kg
).
Time-link light
Setting indicating if clocks are to be linked to other clocks.
Apply light scheme
Setting indicating if the user uses light schemes.
Apply OptiSec
Setting indicating if OptiSec is to be used to influence the
control value heating
and
start
temperature ventilation
.
See also: OptiSec-settings.
Night correction
Setting indicating if a setpoint correction is required during the dark period (night time)
of the day.
Linked to
Setting indicating which light clock is used to determine the dark period times.