Lumina 41/42
House setup
10
If the last feeding cycle is still active when the day change is reached, the control
computer will not interrupt this feeding cycle. The day change will only take place
after the feeding cycle has been completed.
Example: Day change
You have set the day change to 02:00 a.m. As a result, the time period of
every ‘registration day’ is from 02:00 to 01:59 h.
Extra clock
Water clock
Light clock
Setting if you use the extra clock, feed clock and the water clock.
The
Water clock
is used to control the water in the house.
The
Light clock
is used to activate/deactivate the lighting.
The
Extra clock
can be used to control another process in the house.
Clock end time
(With
Extra clock
and
Water clock
)
Setting indicating that the control computer can shift the end time of a clock, for example,
after a power failure.
NO TIME
: The clock has no fixed end time. After a power failure the end time is one
minute before the next start time.
FIXED TIME
: The control computer does not shift this end time. The clock observes
the set end time (therefore the current feeding cycle will be shorter).
SHIFT
: The control computer can shift the end time up to a maximum of the end time
of the following time period. If this setting is selected the extra settings
With clock
overlap
and
Overlap message
will appear.
With overlap clock
(With
Extra clock
and
Water clock
)
Setting indicating the action the control computer must take if the end time of a period
shifts, and overlaps the start time of the next time period (see
Clock end time
).
END
: The control computer deactivates the time clock if the end time overlaps the
start time of the next period.
SHIFT
: The control computer does not deactivate the time clock. The next time
period is moved up (shifted).
Overlap message
(With
Extra clock
and
Water clock
)
Setting indicating the action the control computer must take if one time period overlaps
another:
NONE
: The control computer sends no message and completes the current feeding
cycle.
STOP
: The control computer stops the feed process and gives a loud alarm.
LOUD
: The control computer gives a loud alarm and completes the current feeding
cycle.
SILENT
: The control computer gives a silent alarm and completes the current
feeding cycle.
Water registration
Setting indicating if the amount of water must be registered. A connected water meter is
required. Enter the water meter data at registration page 29.
Light scheme
Setting indicating if the user uses light schemes.
Light control
Setting indicating if the user wants to control light as a percentage.
Measurement
Setting indicating if light measurement in the house is used.
Summary of Contents for F41
Page 1: ...g ...
Page 39: ...Lumina 41 42 Technical specifications 35 ...
Page 41: ...Lumina 41 42 Technical specifications 37 ...
Page 44: ...Lumina 41 42 Appendix Concept feeding systems 40 ...
Page 46: ...Lumina 41 42 Appendix Concept feeding systems 42 ...
Page 47: ...Lumina 41 42 Appendix Concept feeding systems 43 ...
Page 48: ...Lumina 41 42 Appendix Concept feeding systems 44 ...
Page 50: ...Lumina 41 42 Appendix Concept feeding systems 46 ...