Fancom 747
4. Operation
10
Table 1: Alarm values
Value Situation
Explanation
0
Alarm stand by
There is no alarm.
1
Alarm test
Set alarm to 1 to test it; then reset alarm to
stand by by entering the value 0.
5
Alarm
Cancelled
There was an alarm, which has been
cancelled. The computer switches off the
alarm, but the alarm code remains visible.
6
Silent alarm
Alarm message shown on display only.
7
Alarm
temporarily off
Set value to 7 to temporarily switch off the
current alarm. When the alarm situation
has been cancelled, this value will
automatically become 0 again. Always
check that the value has reverted to 0.
8, 9
Alarm blocked
Set the value to 8 or 9 to switch off the
alarm entirely. Only do this when houses
are unoccupied. Do not forget to reset value
to 0
10
Alarm
The type of alarm is shown on the display.
4.5
Function keys (D)
On the front of the computer are 22 function keys. Select a function key by
pressing it. The display will show data relating to this key. A light in the
function key indicates which key has been selected.