Fancom 743
INSTALLER: 5. System settings
14
Stor. silo dem.
FULL
The storage silo is full.
DEMAND
The storage silo demands blend preparation.
FILL
Filling sensor covered
WITHOUT filling sensor
WITH filling sensor
Combination
FILL/MIN sensor
Fig. 2: Storage silo demand illustrated
Max. sensor
Enter the address (in front of the point) and the digital input number (behind
the point) to which the maximum sensor has been connected.
Fill. sensor
Enter the address (in front of the point) and the digital input number (behind
the point) to which the filling sensor has been connected.
Min. sensor
Enter the address (in front of the point) and the digital input number (behind
the point) to which the minimum sensor has been connected.
Relay auger
Enter the address (in front of the point) and the relay number (behind the
point) to which the storage silo auger control has been connected.
Status
The current storage silo auger status: ON (storage silo auger running) or
OFF (storage silo auger idle).
Relay valve
Enter the address (in front of the point) and the relay number (behind the
point) to which the reverse valve control has been connected.
Status
The current pulse giver status: ON (sending pulses) or OFF (not sending
pulses).
Relay pulse
Enter the address (in front of the point) and the relay number (behind the
point) to which the pulse counter has been connected.
Status
The current pulse counter status: ON (pulse counter counting pulses) or OFF
(pulse counter not counting pulses). This can also be used as feed registration
by an external process computer.
Am./feed pulse
Enter how much feed (kg) corresponds to one feed pulse.
Max. sensor
Filling sensor
Min. sensor
FULL
DEMAND
FILL
Max. sensor
Min. sensor
FULL
DEMAND
Max. sensor
Min./Filling sensor
FULL
DEMAND
FILL