irreversible damage to the hood surface. To properly 
clean the unit, the manufacturer recommends using 
the supplied moist wipes, which are also available 
sold separately. 

Insist on original spare parts.

INTENDED USE

The equipment is solely intended to be used to 
extract fumes generated from cooking food in 
non-professional domestic kitchens: any other 
use is improper. Improper use can cause damage 
to persons, things, pets and exempts the Manu-
facturer from any liability.

The equipment can be used by children over the age 
of 8 and by persons with reduced physical, sensory 
and mental abilities, or with no experience or knowl-
edge, as long as they do so under supervision or after 
having received relative instructions regarding safe 
use of the equipment and understanding of the dan-
gers connected to it.
Children are not to play with the equipment. Clean-
ing and maintenance by the user must not be carried 
out by children without supervision.

USE AND CLEANING WARNINGS

Before cleaning or carrying out mainte-
nance operations, disconnect the equip-
ment by removing the plug or switching 

off the main switch.

Do not use the hood with wet hands or bare feet.
Always check that all electrical parts (lights, extractor 
fan) are off when the equipment is not being used. 
The maximum overall weight of any objects placed 
or hung (if applicable) on the hood must not exceed 
1.5 Kg.
Always supervise the cooking process during the use 
of deep-fryers: Overheated oil can catch fire.
Do not leave open, unattended flames under the 
hood.
Do not prepare food over an open flame under the 
hood.
Never use the hood without the metal anti-grease 
filters: in this case, grease and dirt will deposit in the 
equipment and compromise its operation.
Accessible parts of the hood can be hot when used at 
the same time as the cooking appliances.
Do not carry out any cleaning operations when parts 
of the hood are still hot.
There can be a risk of fire if cleaning is not carried out 
according to the instructions and products indicated 
in this booklet.
Disconnect the main switch when the equipment is 
not used for long periods of time.

If other appliances that use gas or other fu-
els are being used at the same time (boiler, 

stove, fireplaces, etc.), make sure the room where 
the fumes are discharged is well-ventilated, in 
compliance with the local regulations.

  INSTALLATION

   only intended for qualified personnel

Before installing the hood, carefully read the chapter 'SAFETY 
INSTRUCTIONS AND WARNINGS'.

TECHNICAL FEATURES

The technical specifications are exhibited on the labels located inside the hood.

POSITIONING

The minimum distance between the highest part of the cooking equip-
ment and the lowest part of the hood is indicated in the installation in-
structions. 

Generally, when the hood is placed over gas cookers, the distance must be at 
least 65 cm (25.6''). However, according to of standard EN60335-2-31, the mini-
mum distance between the cooker and lower part of the hood can be reduced 
to the quota reported in the installation instructions.
Should the instructions for the gas cooker specify a greater distance, this must 
be taken into consideration.
Do not install the hood outdoors and do not expose it to outdoor environment 
(rain, wind, etc.).

ELECTRICAL CONNECTION
(only intended for qualified personnel)

Disconnect the equipment from electrical mains power supply be-
fore carrying out any operations on the hood.
Ensure that the wires inside the hood are not disconnected or cut:

in the event of damage, contact your nearest Servicing Department.
Refer to qualified personnel for electrical connections.
Connection must be carried out in compliance with the provisions of law 
in force.

Before connecting the hood to the electrical mains power supply, check that:
•  voltage supply corresponds with what is reported on the data plate located 

inside the hood;

•  the electrical system is compliant and can withstand the load (see the techni-

cal specifications located inside the hood);

•  the power supply plug and cable do not come into contact with tempera-

tures exceeding 70 °C;

•  the power supply system is effectively and properly connected to earth in 

compliance with regulations in force;

•  the socket used to connect the hood is within reach.

In case of:
•  devices fitted with cables without a plug: the type of plug to use is a ''stand-

ardised'' one. The wires must be connected as follows: yellow-green for earth-
ing, blue for neutral and brown for the phase. The plug must be connected to 
an adequate safety socket.

•  fixed equipment not provided with a power supply cable and plug, or any 

other device that ensures disconnection from the electrical mains, with an 
opening gap of the contacts that enables total disconnection in overvoltage 
category III conditions.

  Said disconnection devices must be provided in the mains power supply in 

compliance with installation regulations.

The yellow/green earth cable must not be cut off by the switch.
The Manufacturer declines all responsibility for failure to comply with the safety 
regulations.

Summary of Contents for POLAR

Page 1: ...N INSTRUCTIONS BOOKLET DE GEBRAUCHSANWEISUNG FR MODE D EMPLOI ES MANUAL DE INSTRUCCIONES RU PL INSTRUKCJA OBS UGI NL HANDLEIDING PT MANUAL DE INSTRU ES DK BRUGSANIVSNINGER SE INSTRUKTIONSBOK FI OHJEKI...

Page 2: ...Max 820 Min POLAR Isola Island 24 Kg POLAR LIGHT Isola Island 24 Kg POLAR BLACK WHITE Isola Island 24 Kg 40 9 152 6 111 7 111 7 40 9 152 6 152 6 40 9 40 9 111 7 111 7 152 6 8x6 2 2 0 15 6 0 316 diamet...

Page 3: ...HITE 350 930 70 430 590 420 2 385 210 8 164 389 4 835 2 154 113 218 170 4 210 114 4 218 170 350 327 590 917 81 430 210 154 164 407 376 822 385 113 POLAR Paret Wall 23 Kg POLAR LIGHT Paret Wall 24 Kg P...

Page 4: ...r die Installation FR Mesures pour l installation ES Medidas para la instalaci n RU PL rodki monta owe NL Maten voor de installatie PT Medidas para a instala o DK M l for installation SE Installations...

Page 5: ...5 T V1 A 2 1 3 1 2 P1 P2 446 P1 113 mm P2 154 mm 8 V2 1 2 A 3 1 2 3 4 8 mm 6 mm...

Page 6: ...de la v lvula antirretorno 5 Fijaci n de la campana 6 7 8 9 RU 5 6 7 8 9 PL Monta zaworu zwrotnego 5 Mocowanie okapu 6 7 8 9 NL Montage terugslagklep 5 verwijderen Kapbevestiging 6 7 8 9 PT Instala o...

Page 7: ...gaben f r die Installation FR Mesures pour l installation ES Medidas para la instalaci n RU PL rodki monta owe NL Maten voor de installatie PT Medidas para a instala o DK M l for installation SE Insta...

Page 8: ...8 8 V1 C 1 2 3 M 4 C B G D x V2 1 2 3 4...

Page 9: ...3 4 5 Monta zaworu zwrotne go 2 ISLAND WALL Zdj metalowe filtry A zamontowa filtry z w glem aktywnym B Po czenia elektryczne C NL Kapbevestiging 1 3 4 5 Montage terugslagklep 2 verwijderen ISLAND WALL...

Page 10: ...10 V3 V3 A 1 2 3 C S C 1 2 1 E V3 A B S 2 4 5 OPTIONAL...

Page 11: ...orme di sicu rezza del Paese di utilizzo deve essere inoltre conforme alle normative Europee sull antidistur bo radio Prima di installare la cappa verificare che la tensione di rete corrisponda a quel...

Page 12: ...stufe caminetti ecc ali mentate a gas o con altri combustibili provvede re ad una adeguata ventilazione del locale in cui avviene l aspirazione dei fumi secondo le norme vigenti INSTALLAZIONE parte ri...

Page 13: ...ri muoverla se presente sul raccordo di uscita aria del motore ISTRUZIONI DI MONTAGGIO parte riservata solo a personale qualificato La cappa ha la possibilit di essere installata in varie configurazi...

Page 14: ...TIMENTO A FINE VITA Il simbolo del cestino barrato riportato sull apparecchiatura in suo pos sesso indica che il prodotto un RAEE cio un Rifiuto derivante dal le Apparecchiature Elettriche ed Elettron...

Page 15: ...iance with safety regulations in the country of use It must also comply with European standards regarding radio antistatic properties Before installing the hood check that the electrical mains power s...

Page 16: ...alling the hood carefully read the chapter SAFETY INSTRUCTIONS AND WARNINGS TECHNICAL FEATURES The technical specifications are exhibited on the labels located inside the hood POSITIONING The minimum...

Page 17: ...ssembly steps apply to all installations for each case follow the specific steps provided for the required installation OPERATION WHEN TO TURN ON THE HOOD Switch on the hood at least one minute before...

Page 18: ...environment The active carbon filters must be replaced on average every 3 4 months under normal conditions of use See assembly instructions to replace the active carbon filters LIGHTING The range hood...

Page 19: ...u beachten dass die Installation mit Befes tigungssystemen die von den mitgelieferten abwei chen elektrische Gefahren und Risiken in Bezug auf die mechanische Abdichtung mit sich bringen kann Die Abzu...

Page 20: ...enst nde falls vorgesehen darf 1 5 kg nicht berschreiten Fritteusen m ssen w hrend des Betriebs berwacht werden Das erhitzte l k nnte Feuer fangen Unter der Haube keine offenen Flammen verwenden Unter...

Page 21: ...UMLUFT FILTRIEREND In dieser Ausf hrung str mt die Luft durch die Aktivkohlefil ter wo sie gereinigt wird und wird anschlie end in den Raum zur ckgeleitet Kontrollieren dass die Aktivkohlefilter in de...

Page 22: ...ckgef hrt Die Aktivkohlefilter m ssen bei normalen Betriebsbedingungen im Durch schnitt alle 3 4 Monate ausgewechselt werden F r den Austausch der Aktivkohlefilter siehe Einbauanleitung BELEUCHTUNG Di...