User Manual
Securope Tempo
7
4.
Coiling the cable for storage
The cable must be coiled as per the picture below:
5.
In case of fall
Maximum
deformation
Calculated with the Fallprotec Securope calculation software
.
See technical file of the system supplied by the installer.
6.
Fall Clearance
The installation must be done so that in case of a fall no equipment touches a sharp edge or
something that can damage it.
The minimum clearance must be superior of the height of fall so that a falling user doesn’t hit an
obstacle during the fall.
The height of fall is the sum of the terms given below:
-
D
Deflection
: the deflection of the rigid anchor line
-
L
blocking
: Locking distance of self retractable lanyard
-
H
Safety
: safety distance (1m)
-
Fall clearance
Required
: minimal height calculated and required in case of a fall
-
Fall clearance
Available
: actual height available between the path and the first obstacle
-
L
Path
: distance from the Life line to the edge
-
L
Lanyard
: lenght of the lanyard (< 2m)
-
L
Absorber
: deployment of the energy absorption system (< 0,8m)
-
H
User
: user’s height