43
»Car System 2« software
EN
At the bottom there are the ports for the outputs (A1 - A12) to which
stop points, parking spaces or branch-off junctions can be connected.
By using the suitable protective resistors, light signals can also be con-
nected to these outputs.
X
Click on the inputs E1 - E11 or the outputs A1 - A12 in order to go to
the relevant settings.
NOTICE
Depending on the functional element you want to use, one of its wire
will have to be connected to the output (A1 - A12) and its other wire to
15 V or 20 V:
Stop point: 20 V
Parking space: 20 V
Branch-off junction: 15 V
Light signal: 15 V with protective resistor!
X
Sensors or push buttons have to be connected with one wire leading to
one input (E1 - E11) and the other wire to 0 V.
Configuring inputs
By clicking on the inputs shown in the picture of the selected module, you
go to the relevant settings to be performed.
Fig. 14: Configuring inputs
Here the required checkback addresses can be specified.