INSTALLATION & ALIGNMENT DATA
Maximum life and minimum maintenance for the coupling
and connected machinery will result if couplings are
accurately aligned. Coupling life expectancy between initial
alignment and maximum operating limits is a function of
load, speed and lubrication.
Values listed are based upon the use of standard
coupling components, standard assemblies and
cataloged allowable speeds.
Values may be combined for an installation or operating condition.
Example: 1060T max. operating misalignment is .016"
parallel plus .018" angular.
NOTE: For applications requiring greater misalignment, refer
application details to the Factory.
Angular misalignment is dimension X minus Y as illustrated
below.
Parallel misalignment is distance P between the hub center
lines as illustrated below.
End float (with zero angular and parallel misalignment) is the
axial movement of the hubs(s) within the cover(s) measured
from “O” gap.
Rexnord Industries, LLC, Coupling Group
428-312
5555 S. Moorland Rd., New Berlin, WI 53151-7953 USA Telephone : 262-796-4060
April 2005
Fax: 262-796-4064 e-mail: [email protected] web: www.rexnord.com
Supersedes 4-99
Installation & Maintenance
• Falk™ Steelflex
®
Spacer Couplings
(Page 6 of 7)
Sizes 1020-1140 & 20-140
•
Type T35
GAP
Y
X
F
F
ANGULAR MISALIGNMENT
P
P
PARALLEL OFFSET MISALIGNMENT
END FLOAT
TABLE 2 — Misalignment & End Float
SIZE
Installation Limits
Operating Limits
Fastener Tightening
Torque Values
Allow
Speed
(rpm)
Lube Wt
Parallel
Offset-P
Angular
(x-y)
Hub Gap
±
10%
Parallel
Offset-P
Angular
(x-y)
End Float
Physical Limit
(Min) 2 x F
Cover
Flange
Max
Inch
Max
mm
Max
Inch
Max
mm
Inch
mm
Max
Inch
Max
mm
Max
Inch
Max
mm
Inch
mm
In. Series
Fasteners
(lb-in)
Metric
Fasteners
(Nm)
In. Series
Fasteners
(lb-in)
lb
kg
1020T
.006
0.15
.003
0.08
.125
3
.012
0.30
.010
0.25
.210
5.33
100
11.3
120
4500
.06
0.03
1030T
.006
0.15
.003
0.08
.125
3
.012
0.30
.012
0.30
.198
5.03
100
11.3
120
4500
.09
0.04
1040T
.006
0.15
.003
0.08
.125
3
.012
0.30
.013
0.33
.211
5.36
100
11.3
120
4500
.12
0.05
1050T
.008
0.20
.004
0.10
.125
3
.016
0.41
.016
0.41
.212
5.38
200
22.6
250
4500
.15
0.07
1060T
.008
0.20
.005
0.13
.125
3
.016
0.41
.018
0.46
.258
6.55
200
23.6
440
4350
.19
0.09
1070T
.008
0.20
.005
0.13
.125
3
.016
0.41
.020
0.51
.259
6.58
200
23.6
440
4125
.25
0.11
1080T
.008
0.20
.006
0.15
.125
3
.016
0.41
.024
0.61
.288
7.32
200
23.6
825
3600
.38
0.17
1090T
.008
0.20
.007
0.18
.125
3
.016
0.41
.028
0.71
.286
7.26
200
23.6
1640
3600
.56
0.25
1100T
.010
0.25
.008
0.20
.188
5
.020
0.51
.033
0.84
.429
10.90
312
35
2940
2440
.94
0.43
1110T
.010
0.25
.009
0.23
.188
5
.020
0.51
.036
0.91
.429
10.90
312
35
2940
2250
1.1
0.51
1120T
.011
0.28
.010
0.25
.250
6
.022
0.56
.040
1.02
.556
14.12
650
73
4560
2025
1.6
0.74
1130T
.011
0.28
.012
0.30
.250
6
.022
0.56
.047
1.19
.551
14.00
650
73
6800
1800
2.0
0.91
1140T
.011
0.28
.013
0.33
.250
6
.022
0.56
.053
1.35
.571
14.50
650
73
8900
1650
2.5
1.14
1020-1070T10
1080-1090T10
1100-1140T10
SAE Grade 8
H
SAE Grade 8
SAE Grade 5
SAE Grade 8
SAE Grade 8
SAE Grade 5
Property Class 10.9
Property Class 10.9
Property Class 8.8
TABLE 3 — Coupling Cover Fastener Identification
SIZE
Inch Series Fasteners
METRIC FASTENERS
Old Style
New Style
H