11. Auto. Rearming (default=disable)
When set as Enable: The system will arm itself again automatically 30 seconds after disarming
the system if no doors are opened. Opening a door after disarming the system will deactivate
the auto rearming feature.
12. AED, Auto Engine Disable (default=disable)
When as Enable: After parking the car, turning the ignition off and opening and then closing
the door the engine disable relay will activate within 10 seconds but the system will still be
disarmed.
- The 10 sec. countdown will be interrupted immediately when opening a door, the countdown
will restart when the door is closed.
- Pressing the remote to arm the system during the 10 sec. countdown will activate the AED
immediately.
- To deactivate the AED:
a) With the system disarmed, remote arming the system then disarming will deactivate the
AED at the same time.
b) With the system armed, remote disarming the system will deactivate the AED at the same
time.
c) By override (when the system is disarmed).
* The AED will not active under valet mode. To disable the AED you must leave the valet
mode.
* When the AED is activated, the system cannot enter the following modes:
a) Code Learning
b) Programming Mode
c) Hazard lights Calibration Mode
d) Anti-hijacking
13. Door Open Alerts (default=disable)
When set as Mode 1:
- The hazard lights will flash when a door is opened with the ignition on until the door is closed
or the ignition is turned off.
* The feature will not be activated if the door is opened whilst the ignition is on.
When set as Mode 2:
- The hazard lights will flash when a door is opened regardless of whether the ignition is on
of off and until the door is closed.
* The feature will be activated regardless of whether the ignition is turned on or off.
14. Total/Comfort Closure (default=disable)
The CH3 wire is designed for the option of automatically closing the windows when arming
the system. This feature requires that the vehicle has Total/Comfort Closure.
When set as Disable:
The CH3 output will not be activated when arming the system but can be controlled as
follows:
- With system armed or disarmed.
- Press and hold button #1+3.
- After 1 sec. the CH3 output will be activated until button #1 is released.
When set as 15, 30 or 40 sec.:
When arming the system the CH3 will send a 15 sec.(or 30, 40) pulse to close the windows
automatically. Pressing the remote to disarm the system during the 15 sec.(or 30, 40) will
deactivate the CH3 output immediately.
15. Disarm with Boot Release (default=disable)
When set as Disable:
When operating the remote boot release the system will remain armed but the shock sensor
will be bypassed. The boot will be protected and shock sensor reactivated 3 sec. after
closing the boot.
When set as Enable:
The system will be disarmed when operating the boot release, the siren will chirp twice and
hazard lights flash twice to confirm.
* The countdown of Auto. Rearming or Passive Arming will be interrupted when operating the