background image

 

 

- 9 -- 9 

#9 Automatic Engine Disable (AED) 

When Set as Enable 
After parking the car, turning the ignition off and opening and then closing the door the immobiliser will activate 

within 10 seconds. 

 

-  The immobiliser will not be active during the 10 second countdown. 
-  After 10 seconds the PIN will be required to disable this feature   

-  With this feature on the system will still be able to enter the arm mode by pressing the remote, via passive/last 

door arming or using Manual Arming 

-  When disarming the system, the AED will still be on and have to deactivated by PIN as follows: 

*Disarm the system by remote 

*Turn the ignition on 

*The LED will flash 10 times slowly after 2 seconds. 

* Press the valet switch once after the LED flashes a number of times equal to the PIN 

 

#10 Passive/Last Door Arming 

When Set as Enable 

The LED will flash rapidly and the system will automatically be armed 30 seconds after closing the last open door, 
bonnet and boot properly.  The siren will chirp and hazard lights flash once to confirm. 

The 30 second countdown will be temporarily interrupted if any of the doors, boot or bonnet are opened. The 

countdown will restart once all doors/boot/bonnet are closed. 

 
#11 Door Locks with Passive/Last Door Arming 

When Set as Enable 

The doors will also be locked when the passive/last door arming feature is activated. 

 
 

#12 Entry Delay 

When Set as Enable 

Triggering of the system will be delayed by 30 seconds when opening the door with the key.  After 30 seconds the siren 
will chirp 10 times to warn and then the system will alarm. 

 

During the 30 second countdown and the 10 warning chirps, the Entry Delay feature still can be deactivated by override 

or by pressing the disarm button of remote to disarm the system. 
 

#13 Interior Light Delay   

Installer only option 

 
#14 Alarm Condition Cycle Duration 

When Set as 30sec. (or 60sec.) 

The siren will sound for 30 seconds (or 60sec) x 1 cycle when the system is triggered and released and the siren will 

sound for 30 seconds (or 60sec) x 3 cycles if the system is triggered all the time. 
 

When Set as 8 cycles 

The siren will sound 30 seconds x 8 cycles regardless of whether the system is triggered and released or triggered all 

the time. 
 

#15 Starter Disable Relay 

Installer only option 

 

#16 Door Open Alert 

When Set as Enable 

If the door is opened when the ignition is on then the hazard lights will flash until the door is closed or the ignition is 

turned off. 
*When Setting #23 and #24 as Enable the anti-hijacking will have the priority and Door Open Alert feature will not be 

functional.  

 

 

#17 Disarm with Boot Release 
When Set as Disable 

When operating the remote boot release the system will remain armed but the shock sensor will be bypassed.    The 

boot will be protected and shock sensor reactivated 3 seconds after closing the boot again. 

 
When Set as Enable 

The system will be disarmed when operating the boot release and the siren will chirp twice and hazard lights flash 

twice to confirm.     

 
The countdown of Auto Rearm or Passive/Last Door Arming will be interrupted if the boot release is operated 

regardless of whether this feature is Disabled or Enabled.    The countdown will be restarted once the boot is closed 

again. 

Summary of Contents for PREDATOR XL2

Page 1: ...icle Security System with Anti Hijack Owner s Manual HELPLINE 0906 700 10 20 All calls charged at 50p min Falcon Security Ltd Unit 9 Tanning Court Warrington Cheshire WA1 2HF UK Internet http www falc...

Page 2: ...LED INDICATOR 3 CLEAR THE TRIGGERS AND SYSTEM ALARMING 3 TRIGGER AND THE SYSTEM ALARMING 4 PANIC MODE 4 EMERGENCY OVERRIDE 5 VALET MODE 5 CAR FINDER 5 SHOCK SENSOR TEMPORARY BYPASS 5 MANUAL ARMING 5...

Page 3: ...ll arm the system without siren chirp Silent Disarm Pressing buttons 1 2 once with system armed will disarm the system without siren chirp The siren will still chirp 4 times if the system has been tri...

Page 4: ...eature 2 has been selected as BOTH then the 1st and 2nd stage of the shock sensor will be bypassed after each stage has been triggered 3 times continually until the system is disarmed and armed again...

Page 5: ...The hazard lights will flash 6 times Press and hold button 4 and 2 seconds later The hazard lights will flash and the siren will chirp till button 4 is released Shock Sensor Temporary Bypass Press Bu...

Page 6: ...ater Repeat the above steps from turning the ignition on and off to program the next feature The system will leave the programming mode automatically if no buttons are pressed within 10 seconds or if...

Page 7: ...LE ENABLE 12 12 CHIRP ENTRY DELAY DISABLE ENABLE 13 13 CHIRP INTERIOR LIGHT DELAY INSTALLER ONLY OPTION 14 14 CHIRP ALARM CONDITION CYCLE DURATION 30 SEC 60 SEC 8 CYCLES 15 15 CHIRP IMMOBILISER RELAY...

Page 8: ...t as Enabled With the system disarmed the doors will be locked 3 seconds after turning the ignition on unless a door is still open The doors will be locked again automatically after stepping on the br...

Page 9: ...chirp 10 times to warn and then the system will alarm During the 30 second countdown and the 10 warning chirps the Entry Delay feature still can be deactivated by override or by pressing the disarm b...

Page 10: ...anti hijacking mode the system will not be allowed to enter Valet mode During the anti hijacking the immobiliser relay will not activate until the ignition is turned off To deactivate anti hijack once...

Page 11: ...PIN Visual Deterrent As a visible deterrent in addition to the flashing dashboard LED your vehicle should have been fitted with the following warning stickers A helpline sticker should also have been...

Reviews: