6.3 COMMISSIONING
Refer to section 2.0 for operation. If Safety Thermostat is activated, refer to section 7.3 to
reset it.
Carry out the following operation:
6.3.1 Turn on mains power supply on.
6.3.2 Ensure Red Neon illuminates.
6.3.3 Turn Temperature Control Knob to 280
o
C.
6.3.4 Ensure Amber Neon illuminates.
6.3.5 Let the pan heat up. When Amber Neon switches off, check the temperature in the
middle of the plate. Ensure the temperature is 280
o
C +/- 20
o
C.
6.3.6 Switch appliance off
This appliance is also provided with a terminal for connection of an
external equipotential conductor. This terminal is an effective electrical
contact with all fixed exposed metal parts of the appliance, and shall
allow the connection of conductor having a nominal cross-section area
of up to 10mm². It is located at the rear of the unit and identified by the
following label and must only be used for bonding purposes.
If the appliance does not operate correctly please refer to section 9.0 and rectify the
problem.
PLEASE FILL OUT THE INFORMATION TABLE ON THE FRONT
COVER AFTER COMMISSIONING.